Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HAMER GENERAL CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HAMER GENERAL CONSTRUCTION, INC. in 266 SOUTH AVE., FANWOOD, NJ 07023 (NAICS 238130). OSHA activity number 341814291.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hamer General Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Hamer General Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
266 SOUTH AVE.
City
FANWOOD
State
NJ
ZIP
07023
Mailing
527 MACKAY AVE., ORADELL, NJ 07649
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.451 F03

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 1, 2016
Abate by
Dec 13, 2016
Penalty
Initial $3,741 · Current $3,741
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  a. 264-268 US 28 (South Ave.) Fanwood, NJ  Employees engaged in framing activities of a commercial building were observed working from a welded tubular frame scaffold that was not inspected by a competent person before each work shift.  Defects observed included, but were not limited to, the scaffold not fully planked between the front uprights and aft guardrail supports on the working levels, scaffold frames missing base plates, scaffold frames supported by unstable objects, scaffold being erected within 3 feet of a 440v power drop, and scaffolds not having safe access to work platforms.   Violation observed on or about October 4, 2016
Recent events (1)
  • — Z (S) $3741

1926.451 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports:     a. 264-268 US 28 (South Ave.) Fanwood, NJ    Employees engaged in framing activities of a commercial building were observed working from a welded tubular frame scaffold that was not fully planked between the front uprights and aft guardrail supports on all working levels.  Employees installing sheathing worked from a welded tubular frame scaffold that had single planking on several levels as a work platform.     Violation observed on or about October 4, 2016
Recent events (1)
  • — Z (S) $0

1926.451 C02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2)(ii): Unstable objects shall not be used to support scaffolds or platform units:   a. 264-268 US 28 (South Ave.) Fanwood, NJ  Employees engaged in commercial framing activities were observed working from a welded tubular frame scaffold that was supported by unstable objects.  The employer authorized the use of scrap wood (2x4) to support scaffold leg when the concrete under the pad was excavated for the installation of new building footings.  Violation observed October 4, 2016
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  a. 264-268 US 28 (South Ave.) Fanwood, NJ  The employer did not ensure safe access to the scaffold platforms when scaffold platforms were more than 2 feet above the point of access.  Employees engaged in commercial framing activities used the scaffold cross braces as access to the working platforms.    Violation observed on or about October 4, 2016  b. 264-268 US 28 (South Ave.) Fanwood, NJ  The employer did not ensure safe access to the scaffold platforms when scaffold platforms were more than 2 feet below the point of access.  Employees engaged in commercial framing activities were observed climbing over a parapet wall and onto a single plank work platform of a welded tubular frame scaffold.  Violation observed on or about October 4, 2016
Recent events (1)
  • — Z (S) $0

1926.451 F06

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.  a. 264-268 US 28 (South Ave.) Fanwood, NJ  The employer authorized the use of a welded tubular frame scaffold erected directly next to a 440V power drop.  Employees engaged in commercial framing activities worked directly next to an energized power drop and were observed egressing the roof by climbing over the conductor to access a scaffold platform.   Violation observed on or about October 4, 2016
Recent events (1)
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 1, 2016
Penalty
Initial $3,741 · Current $3,741
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a. 264-268 US 28 (South Ave.) Fanwood, NJ  The employer did not ensure employees engaged in commercial framing activities working at unprotected working surfaces greater than 6-foot above the next lower level were protected from falls.  Employees removing construction debris from the building roof were observed walking over to the outside edge to drop the debris into a dumpster and were not protected from falls by use of a guardrail system or a personal fall arrest system.  Violation observed on or about October 4, 2016
Recent events (1)
  • — Z (S) $3741

1926.502 I02

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 1, 2016
Penalty
Initial $2,672 · Current $2,672
29 CFR 1926.502(i)(2): All other covers shall be capable of supporting, without failure, at least twice the weight of employees, equipment, and materials that may be imposed on the cover at any one time.  a. 264-268 US 28 (South Ave.) Fanwood, NJ  The employer did not ensure that covers were placed over open holes excavated for the building footings.  Employees engaged in the framing of a commercial structure worked near open holes approximately 3-feet in depth to access the scaffold.   Violation observed on or about October 4, 2016
Recent events (1)
  • — Z (S) $2672

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341814291.