Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SEELY GRAY ROOFING, LLP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SEELY GRAY ROOFING, LLP in 13 RITCHIE AVE., WYOMING, OH 45215 (NAICS 238160). OSHA activity number 341814333.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Seely Gray Roofing, LLP — free Get an email when a new federal OSHA severe-injury report for Seely Gray Roofing, LLP is published. One employer, no account, unsubscribe in one click.
Site address
13 RITCHIE AVE.
City
WYOMING
State
OH
ZIP
45215
Mailing
4639 WAYNES TRACE RD., HAMILTON, OH 45011
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Repeat Gravity 10 1 instance 4 exposed
Issued
Nov 14, 2016
Penalty
Initial $8,231 · Current $2,000 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.    Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    Located on the north side of a steep pitch residential roof structure, employees were observed removing shingles and exposed to a fall hazard while not utilizing an adequate fall protection system. Potential fall heights were measured to be 13.2 feet with a roof pitch of 6 in12.    The Seely Gray Roofing, LLP was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1046045, citation number 1, item number 1 and was affirmed as a final order on 6/30/2015, with respect to a workplace located at 3884 Isabella Ave., Cincinnati, OH 45209.
Recent events (2)
  • — I (R) $2000
  • — Z (R) $8231

View Seely Gray Roofing, LLP's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341814333.