SYRACUSE, NY —
OSHA Inspection: GREENLEAF CABINET MAKERS LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of GREENLEAF CABINET MAKERS LLC in 6691 PICKARD DRIVE, SYRACUSE, NY 13211 (NAICS 337212). OSHA activity number 341818318.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREENLEAF CABINET MAKERS LLC
- Site address
- 6691 PICKARD DRIVE
- City
- SYRACUSE
- State
- NY
- ZIP
- 13211
- Mailing
- 6691 PICKARD DRIVE, SYRACUSE, NY 13211
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337212
- Employees
- 11
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.106 E06 I
- Issued
- Mar 3, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: a) Mixing Room, on or about 10/7/16: Employees dispense from a 5 gallon container of Lacquer Thinner and into a 55 gallon drum of Flammable Waste, and the containers were not grounded.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $2173
1910.106 E06 II
- Issued
- Mar 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) Mixing Room, on or about 10/4/16: Employee dispenses from a 5 gallon container tank to a secondary container with no means of electrically interconnecting the nozzle and the portable container. a) Mixing Room, on or about 10/4/16: Employee dispenses from a paint gun; mixing and or paint cups into a 55 gallon drum with no means of electrically interconnecting the nozzle and the 55 gallon drum.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B09
- Issued
- Mar 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet was not kept free from storage on all sides of paint boot(s): a) Spray Finish Area, on or about 10/4/16: Combustible materials including but not limited to: Wood pieces; cardboard and shelving unit was observed on the left side, right side and back of booth.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Mar 3, 2017
- Abate by
- Mar 23, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Shop Floor, on or about 10/4/16: Employer allowed voluntary use of dust masks and had not supplied employees with Appendix D of the respirator standard.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $2173
1910.134 E01
- Issued
- Mar 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Note: The employer may discontinue an employees medical evaluations when the employee is no longer required to use a respirator. a) Spray Finish Area, on or about 10/4/16: Employee required to wear half face air purifying respirator had not been provided with a medical evaluation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 G02
- Issued
- Mar 3, 2017
- Abate by
- Mar 23, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Throughout the workplace, on or about 10/14/16: Employees expected to respond to incipient fires and were not provided training on the use of fire extinguishers and the hazards involved with incipient stage fire fighting. * ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39 which includes the evacuation requirements of 29 CFR 1910.157(b).
Recent events (2)
- — I (S) $1303.8
- — Z (S) $2173
1910.212 A01
- Issued
- Mar 3, 2017
- Penalty
- Initial $2,897 · Current $1,738 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips: a) Custom Area, on or about 10/4/16: Delta Drill Press was not provided with a chuck and tool guard. b) Custom Building Area, on or about 10/4/16: Delta Drill Press was not provided with a chuck and tool guard.
Recent events (2)
- — I (S) $1738.2
- — Z (S) $2897
1910.242 B
- Issued
- Mar 3, 2017
- Penalty
- Initial $2,897 · Current $1,738 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Wrap Room, on or about 10/4/16: Employees used compressed air for cleaning purposes was measured at approximately 60 p.s.i.
Recent events (2)
- — I (S) $1738.2
- — Z (S) $2897
1910.1052 I02
- Issued
- Mar 3, 2017
- Abate by
- Mar 28, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.1052(i)(2): Employees eyes may contact solutions containing 0.1 percent or greater methylene chloride and the employer did not provide appropriate eye wash facilities within the immediate work area: a) Shop Floor, on or about 10/14/16: No quick drench facility for flushing was made available for use by employees in the event they come in contact with chemicals including but not limited to: methylene chloride contained in Choice Brands Adhesives.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $2173
1910.1052 L01
- Issued
- Mar 3, 2017
- Abate by
- Mar 28, 2017
- Penalty
- Initial $0 · Current $0
1730
General-duty citation text
29 CFR 1910.1052(l)(1): The employer did not provide information and training for each affected employee prior to or at the time of initial assignment to a job involving potential exposure to methylene chloride: a) Shop Floor, on or about 10/14/16: Employees work with Choice Brand Adhesives containing methylene chloride. Employer had not provided information and training prior to the start of their assignment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1052 D02
- Issued
- Mar 3, 2017
- Penalty
- Initial $0 · Current $0
1730
General-duty citation text
29 CFR 1910.1052(d)(2) Employer had employees exposed to methylene chloride and did not perform initial exposure monitoring to determine each affected employee's exposure: a) Shop Floor, on or about 10/14/16: Employee sprayed Choice Brands Adhesiv containing methylene chloride. Employer had not conducted initial monitoring to assess employee exposure.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 337212)