DURYEA, PA —
OSHA Inspection: BOB STACKHOUSE ENTERPRISES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BOB STACKHOUSE ENTERPRISES, INC. in 240 CLARK ROAD, DURYEA, PA 18642 (NAICS 423120). OSHA activity number 341818961.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOB STACKHOUSE ENTERPRISES, INC.
- Site address
- 240 CLARK ROAD
- City
- DURYEA
- State
- PA
- ZIP
- 18642
- Mailing
- 124 WYNCHURCH CIRCLE, PITTSTON, PA 18640
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423120
- Employees
- 3
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.23 A08
- Issued
- Nov 22, 2016
- Abate by
- Jun 1, 2017
- Penalty
- Initial $1,604 · Current $802 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk was not guarded: a) Clark Road, Duryea, PA: A gap of as much as 12 inches between trailers used for storage and flatbed trailers used as a work dock exposed employees to a trip and fall hazard, on or about October 6, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $802
- — Z (S) $1604
1910.23 C01
- Issued
- Nov 22, 2016
- Abate by
- Jun 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground levels were not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder: a) Clark Road, Duryea, PA: The open sides of the work dock, which were as much as 4 feet, 4 inches above the ground, were not equipped with standard railings to protect employees from a fall, on or about October 6, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.23 D01
- Issued
- Nov 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section: a) Clark Road, Duryea, PA: Stairs leading to the work dock were not equipped with standard railings on the open sides exposing workers to a fall, on or about October 6, 2016. CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.141 B01 I
- Issued
- Nov 22, 2016
- Abate by
- Jan 11, 2017
- Penalty
- Initial $1,604 · Current $802 Reduced
General-duty citation text
29 CFR 1910.141(b)(1)(i): Potable water was not provided in all places of employment, for drinking, washing of the person, cooking, washing of foods, washing of cooking or eating utensils, washing of food preparation or processing premises, and personal service rooms: a) Clark Road, Duryea, PA: Potable water for drinking and washing was not available at the worksite, on or about October 6, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $802
- — Z (S) $1604
1910.141 C01 I
- Issued
- Nov 22, 2016
- Abate by
- Jan 11, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(c)(1)(i): Toilet facilities, separate for each sex, were not provided: a) Clark Road, Duryea, PA: Toilet facilities were not available at the site. Employees used a 5-gallon bucket placed in a trailer as a toilet, on or about October 6, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Nov 22, 2016
- Penalty
- Initial $1,604 · Current $802 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Clark Road, Duryea, PA: The unguarded spindle end on a bench grinder exposed workers to an entanglement hazard, on or about October 6, 2016. CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
- — I (S) $802
- — Z (S) $1604
1910.215 A04
- Issued
- Nov 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Offhand grinding machines were not equipped with work rests to support the work: a) Clark Road, Duryea, PA: A bench grinder used by employees to clean and prepare used auto parts for sale was not equipped with a work rest, on or about October 6, 2016. CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 C03 I
- Issued
- Nov 22, 2016
- Abate by
- Jan 11, 2017
- Penalty
- Initial $2,672 · Current $1,336 Reduced
General-duty citation text
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose: a) Clark Road, Duryea, PA: A spliced conductor providing electrical power to a box trailer was not protected exposing workers to an electric shock hazard, on or about October 6, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1336
- — Z (S) $2672
1910.303 G02 I
- Issued
- Nov 22, 2016
- Abate by
- Jan 11, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures: a) Duryea, PA: Bare conductors for a light fixture inside a box trailer were not enclosed or otherwise protected, which exposed workers to an electric shock hazard, on or about October 6, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Nov 22, 2016
- Penalty
- Initial $2,672 · Current $1,336 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Clark Road, Duryea, PA: The live parts of a 110 volt AC receptacle were not covered by a faceplate exposing employees to an electric shock hazard, on or about October 6, 2016. CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
- — I (S) $1336
- — Z (S) $2672
1910.305 C04
- Issued
- Nov 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface. a) Clark Road, Duryea, PA: A snap switch inside a box trailer that was used to provide power to lighting was not equipped with a cover exposing employees to an electric shock hazard, on or about October 6, 2016. CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 IX
- Issued
- Nov 22, 2016
- Abate by
- Jan 11, 2017
- Penalty
- Initial $1,604 · Current $802 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard: a) Clark Road, Duryea, PA: Light fixtures fitted with 200 watt bulbs that were installed in box trailers are not protected from accidental contact and breakage, on or about October 6, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $802
- — Z (S) $1604
More inspections at BOB Stackhouse Enterprises, INC.
View BOB Stackhouse Enterprises, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423120)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341818961.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.