OSHA Inspection: VENTURE ENERGY SERVICES

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of VENTURE ENERGY SERVICES in EOG WELL SITE, LEPORI 2H 15 MILES SOUTH OF GONZALES, TX, GONZALES, TX 78629 (NAICS 213112). OSHA activity number 341827285.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Venture Energy Services — free Get an email when a new federal OSHA severe-injury report for Venture Energy Services is published. One employer, no account, unsubscribe in one click.
Site address
EOG WELL SITE, LEPORI 2H 15 MILES SOUTH OF GONZALES, TX
City
GONZALES
State
TX
ZIP
78629
Mailing
162 CR 283, GILLETT, TX 78116
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
200
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 28, 2017
Abate by
Apr 4, 2017
Penalty
Initial $11,408 · Current $11,408
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of fire and explosion:    On or about October 5, 2016, employees depressurizing the well head were exposed to the hazards associated with ignition of hydrocarbon vapors. The employer installed an open top blow down tank with known ignition sources within 100 feet from the tank, and vented the vapors into the atmosphere, where they could come into contact with ignition sources. Ignition sources ranging from 7 feet to 80 feet in proximity to the tank included but were not limited to live electrical conductors, electrical tools, a gasoline generator and running vehicles.
Recent events (2)
  • — I (S) $11408
  • — Z (S) $11408

1910.138 A

Other-than-serious 1 instance 2 exposed
Issued
Mar 28, 2017
Abate by
Apr 4, 2017
Penalty
Initial $11,408 · Current $6,000 Reduced
29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes.    On or about October 5, 2016, employees were using black nitrile coated gloves not designed to be used in extreme temperature conditions, exposing employees to the hazards of fire and explosions, resulting in burns to the hands.
Recent events (2)
  • — I (O) $6000
  • — Z (S) $11408

1910.151 B

Other-than-serious 1 instance 2 exposed
Issued
Mar 28, 2017
Abate by
Apr 4, 2017
Penalty
Initial $11,408 · Current $0 Reduced
29 CFR 1910.151(b): Adequate first aid supplies were not readily available:    On or about October 5, 2016, and at times prior thereto, employees were exposed to delayed emergency medical treatment for over 20 minutes after sustaining burns from a flash fire. The remote site location off a rural ranch road in Gonzales County required three ambulances to treat, recover and transport five injured workers. The site lacked sterile supplies for immediate treatment of the burns.
Recent events (2)
  • — I (O) $0
  • — Z (S) $11408

1910.307 C

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 28, 2017
Abate by
Apr 4, 2017
Penalty
Initial $11,408 · Current $0 Reduced
29 CFR 1910.307(c): Equipment, wiring and installations of equipment in hazardous (classified) locations was not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:    On or about October 5, 2016,  the employer did not ensure that electrical equipment used or present in a flammable gas environment was intrinsically safe, exposing employees to the hazard of fire and explosions.  Flammable gases were being released from a wellhead in the vicinity of electrical panels, electrical torque wrenches, and energized conductors for a solar panel, none of which were intrinsically safe for hazardous locations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11408

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341827285.