GONZALES, TX —
OSHA Inspection: W.W. WIRELINE, CO.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of W.W. WIRELINE, CO. in EOG WELL SITE, LEPORI 2H 15 MILES SOUTH OF GONZALES, TX, GONZALES, TX 78629 (NAICS 213112). OSHA activity number 341828010.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- W.W. WIRELINE, CO.
- Site address
- EOG WELL SITE, LEPORI 2H 15 MILES SOUTH OF GONZALES, TX
- City
- GONZALES
- State
- TX
- ZIP
- 78629
- Mailing
- 1799 GUADALUPE, PMP 123, LAREDO, TX 78043
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 29, 2017
- Abate by
- Apr 5, 2017
- Penalty
- Initial $5,070 · Current $5,070
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of fire and explosion: On or about October 5, 2016, employees depressurizing the well head were exposed to the hazards associated with ignition of hydrocarbon vapors. An open top blow down tank with known ignition sources was located within 100 feet from the tank, and vapors were vented into the atmosphere, where they could come into contact with ignition sources. Ignition sources ranging from 7 feet to 80 feet in proximity to the tank included but were not limited to live electrical conductors, electrical tools, a gasoline generator and running vehicles.
Recent events (2)
- — I (S) $5070
- — Z (S) $5070
1910.138 A
- Issued
- Mar 29, 2017
- Abate by
- Apr 5, 2017
- Penalty
- Initial $5,070 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes. On or about October 5, 2016, employees were using black nitrile coated gloves not designed to be used in extreme temperature conditions, exposing employees to the hazards of fire and explosions, resulting in burns to the hands.
Recent events (2)
- — I (O) $3000
- — Z (S) $5070
1910.151 B
- Issued
- Mar 29, 2017
- Abate by
- Apr 5, 2017
- Penalty
- Initial $5,070 · Current $0 Reduced
General-duty citation text
29 CFR 1910.151(b): Adequate first aid supplies were not readily available: On or about October 5, 2016, and at times prior thereto, employees were exposed to delayed emergency medical treatment for over 20 minutes after sustaining burns from a flash fire. The remote site location off a rural ranch road in Gonzales County required three ambulances to treat, recover and transport five injured workers. The site lacked sterile supplies for immediate treatment of the burns.
Recent events (2)
- — I (O) $0
- — Z (S) $5070
1910.303 B07 IV
- Issued
- Mar 29, 2017
- Abate by
- Apr 5, 2017
- Penalty
- Initial $2,173 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws: On or about October 10, 2016, and at times prior thereto, an employee was operating two electric hydraulic pumps and both had damaged outer sheathing on the power cords, exposing employees to the hazards of fire and explosions.
Recent events (2)
- — I (O) $1100
- — Z (S) $2173
1910.307 C
- Issued
- Mar 29, 2017
- Abate by
- Apr 5, 2017
- Penalty
- Initial $5,070 · Current $0 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring and installations of equipment in hazardous (classified) locations was not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: On or about October 5, 2016, an employee was operating two electric hydraulic pumps not designed to be used in any explosive, flammable or gas environment, exposing employees to the hazard of fire and explosions. Other electrical equipment on site and exposed to flammable vapors was not approved for hazardous locations.
Recent events (2)
- — I (S) $0
- — Z (S) $5070
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341828010.