Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPARTMENT OF JUSTICE - FEDERAL BUREAU OF PRISONS (BOP) - UNITED STATES PENITENTIARY (USP) - ATWATER

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of U.S. DEPARTMENT OF JUSTICE - FEDERAL BUREAU OF PRISONS (BOP) - UNITED STATES PENITENTIARY (USP) - ATWATER in 1 FEDERAL WAY, ATWATER, CA 95301 (NAICS 922140). OSHA activity number 341828259.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Justice - Federal Bureau of Prisons (BOP) - United States Penitentiary (USP) - Atwater — free Get an email when a new federal OSHA severe-injury report for U.S. Department of Justice - Federal Bureau of Prisons (BOP) - United States Penitentiary (USP) - Atwater is published. One employer, no account, unsubscribe in one click.
Site address
1 FEDERAL WAY
City
ATWATER
State
CA
ZIP
95301
Mailing
1 FEDERAL WAY, ATWATER, CA 95301
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922140
Employees
385
Ownership type
D

2 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 24, 2016
Abate by
Dec 5, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:    Atwater Federal Penitentiary, 10/02/2016: The employer did not provide standard railings on the roofs of the buildings to protect the employees from falling about 24 feet to the ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Oct 24, 2016
Abate by
Nov 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i:    Atwater Federal Penitentiary, 10/02/2016: The compressed air used for cleaning in the maintenance facility was not reduced to 30 p.s.i.