EVANS CITY, PA —
OSHA Inspection: PAUL'S CHROME PLATING, INCORPORATED
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PAUL'S CHROME PLATING, INCORPORATED in 90 PATTISON STREET, EVANS CITY, PA 16033 (NAICS 332813). OSHA activity number 341834687.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PAUL'S CHROME PLATING, INCORPORATED
- Site address
- 90 PATTISON STREET
- City
- EVANS CITY
- State
- PA
- ZIP
- 16033
- Mailing
- 90 PATTISON STREET, EVANS CITY, PA 16033
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 22
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 10, 2017
- Abate by
- May 1, 2017
- Penalty
- Initial $3,622 · Current $2,200 Reduced
M102
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to dust explosion, deflagration, or other fire hazards as the result of two dust collection systems handling combustible metal dusts which were not designed and installed to minimize exposure in the event of a deflagration, explosion, or other uncontrolled fire event: a) Outside of the Plating Room, on or about October, 13 2016 - All components of the two AAF International Optiflo RC dust collectors and the associated duct work were not bonded and grounded. b) Outside of the Plating Room, on or about October 13, 2016 - Two AAF International Optiflo RC dust collectors were not provided with explosion protection. Employees work adjacent to the dust collectors in the Plating Room. c) In the Polish Room and Aluminum Polish Room, on or about October 13, 2016 - Exhaust air from both AAF International Optiflo RC dust collectors was recycled back into the Polish Room and Aluminum Polish Room.
Recent events (2)
- — I (S) $2200
- — Z (S) $3622
1910.95 G06
- Issued
- Feb 10, 2017
- Penalty
- Initial $3,622 · Current $2,200 Reduced
8111
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels: a) In the Polish Room, on or about November 8, 2016 - The employer failed to obtain an annual audiogram for a polisher who was exposed to noise at an 8-hour time-weighted average of 88.9 decibels. Employees received audiograms from Apple Mobile Medical in June 2009. b) In the Polish Room, on or about November 8, 2016 - The employer failed to obtain an annual audiogram for a polisher who was exposed to noise at an 8-hour time-weighted average of 94.6 decibels. Employees received audiograms from Apple Mobile Medical in June 2009.
Recent events (2)
- — I (S) $2200
- — Z (S) $3622
1910.1000 A02
- Issued
- Feb 10, 2017
- Abate by
- May 1, 2017
- Penalty
- Initial $3,622 · Current $2,200 Reduced
0730
General-duty citation text
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of copper dust listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 1 mg/m3: a) In the Polish Room, on or about November 8, 2016 - A Polisher was exposed to copper dust at a time weighted average exposure of 1.22 mg/m3. This level is 1.22 times the permissible exposure limit of 1 mg/m3 as a time weighted average concentration. Sampling was performed by an OSHA compliance officer on November 8, 2016 for 456 minutes and zero exposure was assumed for the unsampled portion of the shift.
Recent events (2)
- — I (S) $2200
- — Z (S) $3622
1910.94 B02
- Issued
- Feb 10, 2017
- Abate by
- May 1, 2017
- Penalty
- Initial $0 · Current $0
0730
General-duty citation text
29 CFR 1910.94(b)(2): Where dry grinding, dry polishing or buffing was performed, and employee exposure, without regard to the use of respirators, exceeded the permissible exposure limits prescribed in 1910.1000 or other sections of this part, a local exhaust ventilation system was not provided and used to maintain employee exposures within the prescribed limits: a) In the Polish Room, on or about November 8, 2016 - The employer failed to use a local exhaust ventilation system to lower a Polisher's exposure to copper dust below the permissible exposure limit.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Paul'S Chrome Plating, Incorporated
View Paul'S Chrome Plating, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 332813)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341834687.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.