Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GARY MUELLER

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GARY MUELLER in 4545 W. PINE ST., APPLETON, WI 54914 (NAICS 561790). OSHA activity number 341837870.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gary Mueller — free Get an email when a new federal OSHA severe-injury report for Gary Mueller is published. One employer, no account, unsubscribe in one click.
Establishment
GARY MUELLER
Site address
4545 W. PINE ST.
City
APPLETON
State
WI
ZIP
54914
Mailing
142 N. WESTERN AVE. UNIT F, NEENAH, WI 54956
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.451 G01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Oct 25, 2016
Abate by
Nov 23, 2016
Penalty
Initial $1,604 · Current $0 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:     (a)  At the 4545 W. Pine St., Unit K, Appleton, WI jobsite; fall protection was not utilized while performing caulking activities to an exterior of a building.  This exposed an employee to a fall hazard of approximately 11'.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1604

1926.451 B05 I

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Oct 25, 2016
Abate by
Nov 23, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end.  (a)  At the 4545 W. Pine St., Unit K, Appleton, WI jobsite; the scaffold pick installed on the scaffold extended more than 12 inches past the upright exposing employees to a tipping hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Oct 25, 2016
Abate by
Nov 23, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.  (a)  At the 4545 W. Pine St., Unit K, Appleton, WI jobsite; the employer did not train employees on the proper use and erection of the scaffold.  The employees were working from a platform made up of scaffold plank, scaffold board, plywood, and 2x10 boards not secured together.  This exposed employee(s) to tipping hazards due to its construction.