Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HENDON RESTORATION, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HENDON RESTORATION, LLC in 17477 US HWY 72, ATHENS, AL 35611 (NAICS 561720). OSHA activity number 341838340.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hendon Restoration, LLC — free Get an email when a new federal OSHA severe-injury report for Hendon Restoration, LLC is published. One employer, no account, unsubscribe in one click.
Site address
17477 US HWY 72
City
ATHENS
State
AL
ZIP
35611
Mailing
17477 US HWY 72, ATHENS, AL 35611
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561720
Employees
10
Ownership type
A

6 citations on file for this inspection.

1910.106 D05 III

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 28, 2017
Penalty
Initial $1,847 · Current $1,108 Reduced
29 CFR 1910.106(d)(5)(iii): The storage of flammable or combustible liquids required and used for the maintenance and operation of building and operation of equipment was not kept in closed metal containers stored in a storage cabinet or in safety cans or in an inside storage room not having a door that opens into that portion of the building used by the public:  (a) On or about 10/11/2016 - in the storage area, diesel was stored in a 5-gallon portable container that was not closed.
Recent events (2)
  • — I (S) $1108.2
  • — Z (S) $1847

1910.106 D07 I B

Other-than-serious 1 instance 2 exposed
Issued
Feb 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(7)(i)(b):  A portable fire extinguisher having a rating of not less than 12-B units was not located not less than 10 feet, nor more than 25 feet, from any Category 1, 2, or 3 flammable liquid storage area located outside of a storage room but inside a building as required.  (a) On or about 10/11/2016 - in the warehouse area, the fire extinguisher stored not less that 10 feet nor more than 25 feet from the portable gasoline and diesel containers was empty.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C04

Other-than-serious 1 instance 2 exposed
Issued
Feb 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:   (a) On or about 10/11/2016 - in the warehouse area, the fire extinguisher mounted near the steps was not maintained in a fully charged condition.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 E01

Other-than-serious 1 instance 3 exposed
Issued
Feb 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) On or about 10/11/2016 - at 17477 US Hwy 72, Athens, AL, employees were not provided a medical evaluation before being fit tested or required to use a respirator at a job site.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 M02 I

Other-than-serious 1 instance 3 exposed
Issued
Feb 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(m)(2)(i): The employer did not establish a record of the qualitative and quantitative fit tests administered to an employee which included the information required by 29 CFR 1910.134(m)(2)(i)(A) through (m)(2)(i)(E):  (a) On or about 10/11/2016 - at 17477 US Hwy 72, Athens, AL, a record was not available for employees who had been administered a fit test.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1030 G02 I

Other-than-serious 1 instance 6 exposed
Issued
Feb 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(g)(2)(i): The employer did not ensure that each employee with occupational exposure participated in a training program:  (a) On or about 10/11/2016 - at 17477 US Hwy 72, Athens, AL, training had not been provided to employees with occupational exposure to bloodborne pathogens.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341838340.