Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENERAL IRON INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GENERAL IRON INDUSTRIES, INC. in 1909 N. CLIFTON AVE., CHICAGO, IL 60614 (NAICS 423930). OSHA activity number 341840858.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Iron Industries, INC. — free Get an email when a new federal OSHA severe-injury report for General Iron Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1909 N. CLIFTON AVE.
City
CHICAGO
State
IL
ZIP
60614
Mailing
1909 N. CLIFTON AVE., CHICAGO, IL 60614
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
100
Ownership type
A

5 citations on file for this inspection.

1910.178 P01

Deleted Serious Gravity 5 2 instances 5 exposed
Issued
Feb 6, 2017
Penalty
Initial $4,848 · Current $0 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s)  (a) Facility Wide- On October 20, 2016, the employer failed to ensure that powered industrial trucks #36 and #76 operating with damaged headlights and strobe lights were removed from service until they had been restored to a safe operating condition.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4848

1910.212 A01

Other-than-serious 3 instances 3 exposed
Issued
Feb 6, 2017
Abate by
Mar 10, 2017
Penalty
Initial $5,704 · Current $5,704
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Non-Ferrous Plant - On or about October 17, 2016, the employer failed to ensure that adequate methods of guarding were used to protect employees from the point of operation and moving parts on three alligator sheers located in the department.              In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $5704
  • — Z (S) $5704

1910.23 E01

Other-than-serious 1 instance 3 exposed
Issued
Feb 6, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:  (a) Scale 2 - On or about October 17, 2016, the employer did not ensure that stairs leading to a trailer office accessed by employees was equipped with an intermediate rail.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 1 instance 15 exposed
Issued
Feb 6, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  (a) Facility Wide - On or about October 17, 2016, the employer did not ensure that periodic inspections of the energy control procedures were conducted at least annually to ensure that the procedures and requirements of the energy control program were properly implemented and followed by employees.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 J04 V

Deleted Other-than-serious 2 instances 5 exposed
Issued
Feb 6, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(4)(v): The disconnecting means was not readily accessible:  If more than one disconnect is provided for the same equipment, only one need be readily accessible.  (a) Non-ferrous sorting equipment - On or about October 17, 2016, the employer did not ensure that the means for disconnecting the shaker machines M66 and M66a was readily accessible.       No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View General Iron Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341840858.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.