JACKSONVILLE, FL —
OSHA Inspection: HOAR CONSTRUCTION, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of HOAR CONSTRUCTION, LLC in 951 ALLEGHENY RD, JACKSONVILLE, FL 32212 (NAICS 236220). OSHA activity number 341844769.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOAR CONSTRUCTION, LLC
- Site address
- 951 ALLEGHENY RD
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32212
- Mailing
- TWO METRO PLEX DR, BIRMINGHAM, AL 35203
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- Mar 17, 2017
- Penalty
- Initial $12,675 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. On or about October 5, 2016, on the peak of the roof of the commissary, the Hoar Construction Safety Manager and electrician employees of Consolidated Electrical Contractors & Engineers, Inc. were exposed to a 30 feet fall hazard from the roof in that they were not protected by a fall protection system. b. On or about October 5, 2016, the employer did not erect guard rails or provide anchor points for personal fall protection at the unprotected edge above the meat manager office, exposing employees of Hoar Construction, electrician employees of Consolidated Electrical Contractors and Engineers, Inc., and employees of Mohr Services to a 10 feet fall hazard from the top of the cooler to the office below.
Recent events (2)
- — I (S) $0
- — Z (S) $12675
1926.501 B04 II
- Issued
- Mar 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers: a. On or about October 5, 2016, at the NAS Jacksonville Commissary above the meat, produce, frozen foods, and dairy coolers and freezers, Hoar Construction employees, a Mohr Service employee installing refrigeration controls, and electrician employees of Consolidated Electrical Contractors & Engineers were exposed to trip hazards from 6 to 12 inch-wide floor holes between the top edges of the coolers and the surrounding walls in that covers had not been placed over the holes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Hoar Construction, LLC
View Hoar Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341844769.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.