2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: TENCOM LTD.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TENCOM LTD. in 7134 RAILROAD ST., HOLLAND, OH 43528 (NAICS 327215). OSHA activity number 341848125.

Watch Tencom LTD. — free Get an email when a new federal OSHA severe-injury report for Tencom LTD. is published. One employer, no account, unsubscribe in one click.
Establishment
TENCOM LTD.
Site address
7134 RAILROAD ST.
City
HOLLAND
State
OH
ZIP
43528
Mailing
7134 RAILROAD ST., HOLLAND, OH 43528
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327215
Employees
35
Ownership type
A

6 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 5 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $6236.00 · Current $4053.00 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    a. Tencom Ltd. located in Holland, OH:  On or about October 18, 2016, the employer did not ensure employees operating equipment such as but not limited to the S-4 saw, located in building #2, were trained as authorized employees under the company's lockout program.  Employees were performing operations such as, but not limited to, changing out saw pads which requires the application of lockout devices.
Recent events (2)
  • — I (S) $4053.4
  • — Z (S) $6236

1910.147 D04 I

Serious Gravity 5 2 instances 12 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees.  a. Tencom Ltd. located in Holland, OH:  On or about October 17, 2016, the employer did not ensure an employee performing a blade change on the 2-5 saw located in building #2, placed a lockout device on the pneumatic hose after disconnecting the pneumatic hose from the pneumatic solenoid.  b. Tencom Ltd. located in Holland, OH:  On or about October 17, 2016, the employer did not ensure employees placed a lockout device on the electrical disconnect and the pneumatic disconnect for the 2-4 saw located in building #2 prior to changing out the saw pads.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $0.00 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments.  a. Tencom Ltd. located in Holland, OH:  On or about October 9, 2016, the employer did not ensure an employee had received training on when to verify zero energy on electrical systems and what electrical protective equipment needed to be worn when working on electrical systems.  The employee did not verified with test equipment that the electrical limit switch on the Kalamazoo saw, located in building#2, was deenergized prior disconnecting the switch from the electrical system and the employee was not provided with the proper electrical protective equipment when working on the electrical system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3741

1910.333 A

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices were not consistent with the nature and extent of the associated electrical hazards.  a. Tencom Ltd. located in Holland, OH:  On or about October 9, 2016, the employer did not ensure safety related work practices were followed when an employee failed to verify zero energy on an electrical system and did not wear electrical protective equipment prior to performing work on the 110 volt electrical interlock for the Kalamazoo saw located in building #2.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 B02 IV B

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.333(b)(2)(iv)(B): A qualified person did not use test equipment to test the circuit elements and electrical parts of equipment to which employees were exposed and did not verify that the circuit elements and equipment parts were deenergized. The test did not determine if any energized condition existed as a result of inadvertently induced voltage or unrelated voltage backfeed even though specific parts of the circuit had been deenergized and presumed to be safe. If the circuit to be tested is over 600 volts, nominal, the test equipment shall be checked for proper operation immediately after this test.  a. Tencom Ltd. located in Holland, OH:  On or about October 9, 2016, the employer did not ensure an employee verified with test equipment that the electrical limit switch on the Kalamazoo saw located in building#2 was deenergized prior disconnecting the switch from the electrical system and installing a new switch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 I

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards were not provided with, and did not use, electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed.   a. Tencom Ltd. located in Holland, OH:  On or about October 9, 2016, the employer did not ensure An employee performing electrical work on the 110 volt electrical interlock for the Kalamazoo saw, located in building #2, was not provided with electrical protective equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341848125.