FLORHAM PARK, NJ —
OSHA Inspection: PABLO'S CONSTRUCTION, LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PABLO'S CONSTRUCTION, LLC. in 8 VENTURI COURT, FLORHAM PARK, NJ 07932 (NAICS 238170). OSHA activity number 341851145.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PABLO'S CONSTRUCTION, LLC.
- Site address
- 8 VENTURI COURT
- City
- FLORHAM PARK
- State
- NJ
- ZIP
- 07932
- Mailing
- 123 JOHNSON STREET, NEWARK, NJ 07105
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.25 A
- Issued
- Apr 11, 2017
- Penalty
- Initial $2,173 · Current $1,760 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: a) 8 Venturi Court, Florham Park, NJ. Employees were exposed to injury from trips and falls and from protruding nails as old siding material was allowed to accumulate in the immediate work area around the pump jack scaffolding. Violation observed on or about 10/18/2016.
Recent events (2)
- — I (S) $1760
- — Z (S) $2173
1926.451 B05 II
- Issued
- Apr 11, 2017
- Penalty
- Initial $3,803 · Current $1,760 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end: a) 8 Venturi Court, Florham Park, NJ. Employees were exposed to falls of up to 12 feet, 10 inches to the ground below from pump jack scaffolding as the 2 ends of the platform extended over their supports by 4 and 5 feet lengths with no end guardrails blocking employees from accessing the cantilevered end. Violation observed on or about 10/18/2016.
Recent events (2)
- — I (S) $1760
- — Z (S) $3803
1926.451 F03
- Issued
- Apr 11, 2017
- Penalty
- Initial $3,259 · Current $1,760 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) 8 Venturi Court, Florham Park, NJ. Employees were exposed to falls of up to 12 feet, 10 inches to the ground below from pump jack scaffolding as a competent person had not inspected the scaffold or its components for defects as shown by the 2 ends of the platform extending over their supports by 4 and 5 feet lengths and as shown by the lack of fall protection for employees working on the scaffolding. Violation observed on or about 10/18/2016.
Recent events (2)
- — I (S) $1760
- — Z (S) $3259
1926.451 G01 VII
- Issued
- Apr 11, 2017
- Penalty
- Initial $3,803 · Current $1,760 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) 8 Venturi Court, Florham Park, NJ. Employees were exposed to falls of up to 12 feet, 10 inches to the ground below from pump jack scaffolding as the scaffolding was lacking end rail fall protection and any fall protection netting between the work rest and the work platform. Violation observed on or about 10/18/2016.
Recent events (2)
- — I (S) $1760
- — Z (S) $3803
1926.1053 B04
- Issued
- Apr 11, 2017
- Penalty
- Initial $1,630 · Current $1,760
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) 8 Venturi Court, Florham Park, NJ. An approximate 20 foot extension ladder was used as the pump jack scaffold's work rest which is not the intended use for a ladder and neither the scaffold manufacturer nor any ladder manufacture would approve this type of use for a ladder. Violation observed on or about 08/30/2016.
Recent events (2)
- — I (S) $1760
- — Z (S) $1630
More inspections at Pablo'S Construction, LLC.
View Pablo'S Construction, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341851145.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.