Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BROTHERS ROOFING & CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BROTHERS ROOFING & CONSTRUCTION, INC. in 3222 S. PARKWAY, NORTHBROOK, IL 60062 (NAICS 238160). OSHA activity number 341851434.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brothers Roofing & Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Brothers Roofing & Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3222 S. PARKWAY
City
NORTHBROOK
State
IL
ZIP
60062
Mailing
2734 W. TOUHY AVE., CHICAGO, IL 60645
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

13 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 16, 2016
Abate by
Nov 22, 2016
Penalty
Initial $3,527 · Current $1,763 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.     a) On or about October 20, 2016, employees were exposed to eye and face injuries while operating a hot tar kettle.         In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1763
  • — Z (S) $3527

1926.150 C01 VI

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 16, 2016
Abate by
Nov 22, 2016
Penalty
Initial $2,352 · Current $1,176 Reduced
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite:      a) On or about October 20, 2016, the employer did not provide a fire extinguisher rated not less than 10B where more than 5 pounds of propane was provided for use and was being used during roofing operations.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1176
  • — Z (S) $2352

1926.252 A

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 16, 2016
Abate by
Nov 22, 2016
Penalty
Initial $2,352 · Current $1,176 Reduced
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s):        a) On or about October 20, 2016, employees were exposed to the hazard of being struck by material and debris that was being thrown from the roof deck at an elevation of approximately 26 feet.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1176
  • — Z (S) $2352

1926.350 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 16, 2016
Abate by
Nov 22, 2016
Penalty
Initial $2,352 · Current $1,176 Reduced
29 CFR 1926.350(a)(2): When cylinders were hoisted, they were not secured on a cradle, slingboard, or pallet.      a) On or about October 20, 2016, a 50 pound liquid petroleum (LP) gas cylinder was hoisted using a choker sling.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1176
  • — Z (S) $2352

1926.350 G03

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 16, 2016
Penalty
Initial $2,352 · Current $1,176 Reduced
29 CFR 1926.350(g)(3): Torches were not lighted by friction lighters or other approved devices.     a) On or about October 20, 2016, a butane lighter was used to light torches.       No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $1176
  • — Z (S) $2352

1926.501 B03

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 16, 2016
Abate by
Nov 22, 2016
Penalty
Initial $4,115 · Current $2,057 Reduced
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems:       a) On or about October 20, 2016, employees were exposed to the hazard of falling approximately 26 feet while operating a manual material hoist to raise and lower materials and equipment to and from the edge of the roof deck.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2057
  • — Z (S) $4115

1926.501 B10

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 16, 2016
Penalty
Initial $4,115 · Current $2,057 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:       a)  On or about October 20, 2016, employees were exposed to the hazard of falling approximately 26 feet while performing manual roofing work activities without the use of fall protection or a warning line and safety monitoring system.       No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $2057
  • — Z (S) $4115

1926.502 D18

Serious Gravity 5 3 instances 1 exposed
Issued
Nov 16, 2016
Abate by
Nov 22, 2016
Penalty
Initial $2,352 · Current $0 Reduced
29 CFR 1926.502(d)(18): Body belts, harnesses, and components were used to hoist materials:     a) On or about October 20, 2016, fall protection components were used for hoisting materials.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2352

1926.552 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 16, 2016
Abate by
Dec 22, 2016
Penalty
Initial $2,940 · Current $1,470 Reduced
29 CFR 1926.552(a)(1): The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators. Where manufacturer's specifications are not available, the limitations assigned to the equipment were not based on the determinations of a professional engineer competent in the field:         a) On or about October 20, 2016, a manually operated material handling hoist at the roof edge was counterweighted with miscellaneous roofing materials and equipment, and not with approved counterweights.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2940

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 16, 2016
Penalty
Initial $2,940 · Current $2,940
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:     a) On or about October 20, 2016, employees were exposed to the hazard of falling approximately 26 feet where a portable extension ladder was not extended at least three feet above the landing surface of the building.      No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $2940

1926.100 A

Repeat Gravity 5 1 instance 2 exposed
Issued
Nov 16, 2016
Penalty
Initial $4,703 · Current $2,344 Reduced
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:        a) On or about October 20, 2016, employees were exposed to head injury while working without protective helmets in areas below hoisting and debris removal operation.      Brothers Roofing & Construction, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.100 (a) which was contained in OSHA inspection number 771301, citation 2, item 1, and was affirmed as a final order on January 29, 2013, with respect to a worksite located at 2337 N. Campbell Ave., Chicago, Illinois.     Brothers Roofing & Construction, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.100 (a) which was contained in OSHA inspection number 109799, citation 1, item 1, and was affirmed as a final order on December 28, 2011, with respect to a worksite located at 3857 N. Parkway Drive, Northbrook, Illinois.     No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (R) $2344
  • — Z (R) $4703

1926.501 B01

Repeat Gravity 10 1 instance 2 exposed
Issued
Nov 16, 2016
Abate by
Nov 22, 2016
Penalty
Initial $8,231 · Current $4,015 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:        a) On or about October 20, 2016, employees were exposed to the hazard of falling approximately 26 feet while disposing of roofing materials and debris at the roof edge where fall protection had not been provided.     Brothers Roofing & Construction, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(1) which was contained in OSHA inspection number 109799, citation 1, item 2, and was affirmed as a final order on December 28, 2011, with respect to a worksite located at 3857 N. Parkway Drive, Northbrook, Illinois.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (R) $4015
  • — Z (R) $8231

1926.502 F01 III

Repeat Gravity 5 3 instances 4 exposed
Issued
Nov 16, 2016
Abate by
Nov 22, 2016
Penalty
Initial $5,879 · Current $2,500 Reduced
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines:     a) On or about October 20, 2016, access paths were not provided between the work areas and debris disposal areas, hoist areas, storage areas, and access points.     Brothers Roofing & Construction, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.502 (f)(1)(iii) which was contained in OSHA inspection number 109799, citation 1, item 3b, and was affirmed as a final order on December 28, 2011, with respect to a worksite located at 3857 N. Parkway Drive, Northbrook, Illinois.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (R) $2500
  • — Z (R) $5879

View Brothers Roofing & Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341851434.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.