Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SIQUEIROS PLASTERING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SIQUEIROS PLASTERING in 8912 MARKS ST., EL PASO, TX 79904 (NAICS 238140). OSHA activity number 341858173.

Watch Siqueiros Plastering — free Get an email when a new federal OSHA severe-injury report for Siqueiros Plastering is published. One employer, no account, unsubscribe in one click.
Site address
8912 MARKS ST.
City
EL PASO
State
TX
ZIP
79904
Mailing
750 AGUA BRAVA, EL PASO, TX 79928
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

4 citations on file for this inspection.

1926.21 B02

Deleted Serious Gravity 10 4 instances 8 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $0.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  Construction site: On or about August 14, 2016, employees were not trained to recognize or eliminate electrical and fall hazards in the workplace. This condition exposed employees to fall hazards greater than 6-feet and electrical shock hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $3741
  • — Z (S) $3741

1926.451 F06

Serious Gravity 10 4 instances 8 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $1000.00 Reduced
29 CFR 1926.451(f)(6): The clearance between scaffolds and 13,800 volt un-insulated power lines were not kept at a minimum of 10 feet away when scaffolds were erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines:    Construction site: On or about October 14, 2016, and at times thereof, employees performing plastering work on a framed scaffold were exposed to un-insulated electrical power distribution lines (13,800 volt) within 10-feet from the scaffolds. This condition exposed employees to electrical shock hazards.
Recent events (3)
  • — F (S) $1000
  • — C (S) $3741
  • — Z (S) $3741

1926.1053 B01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $2672.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access.    Construction site: On or about October 14, 2016, employees were using a 20-foot aluminum extension ladder that was not extended at least 3-feet above a roof landing surface. This condition exposed employees to fall hazards greater than 6-feet.
Recent events (3)
  • — F (S) $1000
  • — C (S) $2672
  • — Z (S) $2672

1926.1053 B12

Deleted Serious Gravity 5 2 instances 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(12): Ladders did not have nonconductive side rails when they were used where the employee or the ladder could contact exposed energized electrical equipment, except as provided in 1926.951(c)(1) of this part.  Construction site: On or about October 14, 2016, employees were using a 20-foot aluminum extension ladder in an area were insulated electrical lines ran approximate 2 to 3-feet away from the ladder.  This condition exposed employees to electrical shocks hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341858173.