Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NEW YORK CONSTRUCTION & RENOVATION INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NEW YORK CONSTRUCTION & RENOVATION INC in JUNCTION PLAYGROUND 34TH AVE AND 96TH STREET, JACKSON HEIGHTS, NY 11372 (NAICS 236220). OSHA activity number 341858728.

Watch NEW York Construction & Renovation INC — free Get an email when a new federal OSHA severe-injury report for NEW York Construction & Renovation INC is published. One employer, no account, unsubscribe in one click.
Site address
JUNCTION PLAYGROUND 34TH AVE AND 96TH STREET
City
JACKSON HEIGHTS
State
NY
ZIP
11372
Mailing
992 CONEY ISLAND AVE, BROOKLYN, NY 11230
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236220
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.451 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $3622.00
29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm):  a)  On or about October 11, 2015 - job site at the Junction Playground, 34th Ave and 96th Street, Jackson Heights, NY   an employee was performing masonry work on a tubular welded framed scaffold that was not fully planked.  WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $3622

1926.451 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:  a)  On or about October 11, 2015 - job site at the Junction Playground, 34th Ave and 96th Street, Jackson Heights, NY   an employee was performing masonry work on a tubular welded framed scaffold that was not bearing on base plates or  mud sills.   WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  a)  On or about October 11, 2015 - job site at the Junction Playground, 34th Ave and 96th Street, Jackson Heights, NY   an employee was performing masonry work on a tubular welded framed scaffold that did not have a access ladder.   WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  a)  On or about October 11, 2015 - job site at the Junction Playground, 34th Ave and 96th Street, Jackson Heights, NY   an employee was performing masonry work on a tubular welded framed scaffold, approximately 11 feet above the next  lower level, without fall protection.   WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $0

1926.452 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:  a)  On or about October 11, 2015 - job site at the Junction Playground, 34th Ave and 96th Street, Jackson Heights, NY   an employee was performing masonry work on a tubular welded framed scaffold that was missing cross braces.   WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341858728.