OWASSO, OK —
OSHA Inspection: OKLAHOMA SPECIALTIES INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OKLAHOMA SPECIALTIES INC. in 7007 N. 115TH EAST AVE., OWASSO, OK 74055 (NAICS 332111). OSHA activity number 341862985.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OKLAHOMA SPECIALTIES INC.
- Site address
- 7007 N. 115TH EAST AVE.
- City
- OWASSO
- State
- OK
- ZIP
- 74055
- Mailing
- P.O. BOX 455, OWASSO, OK 74055
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332111
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 A06
- Issued
- Jan 10, 2017
- Abate by
- Jan 26, 2017
- Penalty
- Initial $2,138 · Current $1,283 Reduced
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were not maintained in a legible condition: On or about October 25, 2016, the employer did not ensure that all nameplates or markings were maintained in a legible condition on the Caterpillar powered industrial truck used at the establishment. Employees were exposed to the hazard of being struck by loads.
Recent events (2)
- — I (S) $1282.8
- — Z (S) $2138
1910.178 L01 I
- Issued
- Jan 10, 2017
- Abate by
- Jan 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about October 25, 2016, the employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation. Employees were exposed to the hazard of being struck by load.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jan 10, 2017
- Abate by
- Jan 23, 2017
- Penalty
- Initial $1,604 · Current $962 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about October 25, 2016, HEM Band Saw, unused portions of blade were not guarded. Employees were exposed to the hazard of being caught in point of operation and/or being struck by blade.
Recent events (2)
- — I (S) $962.4
- — Z (S) $1604
1910.305 G02 II
- Issued
- Jan 10, 2017
- Abate by
- Jan 23, 2017
- Penalty
- Initial $1,604 · Current $962 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: On or about October 25, 2016, flexible cord for portable light over Ingersoll mill was spliced into an orange extension cord. Employees were exposed to the hazard of electric shock and/or hazards associated with fire.
Recent events (2)
- — I (S) $962.4
- — Z (S) $1604
1910.305 G01 IV D
- Issued
- Jan 10, 2017
- Abate by
- Jan 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces. On or about October 25, 2016, flexible cord for portable light over Ingersoll mill was spliced into an orange extension cord and attached to building electrical conduit. Employees were exposed to the hazard of electric shock and/or the hazards associated with fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 III
- Issued
- Jan 10, 2017
- Abate by
- Jan 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Flexible cords used as permitted in paragraphs (g)(1)(ii)(C), (g)(1)(ii)(G), or (g)(1)(ii)(I) of 29 CFR 1910.305 were not equipped with an attachment plug and energized from an approved receptacle outlet: On or about October 25, 2016, yellow extension cord was used to power portable light used on Ingersoll mill. Extension cord was not equipped with an attachment plug. The extension cord was attached to the light and was wired to the control panel of the mill. Employees were exposed to the hazard of electric shock and/or the hazards associated with fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Oklahoma Specialties INC.
View Oklahoma Specialties INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332111)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341862985.