OSHA Inspection: MOUNT VERNON CHEMICALS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MOUNT VERNON CHEMICALS, LLC in 2905 HIGHWAY 280 EAST, OPELIKA, AL 36804 (NAICS 325188). OSHA activity number 341863140.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mount Vernon Chemicals, LLC — free Get an email when a new federal OSHA severe-injury report for Mount Vernon Chemicals, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2905 HIGHWAY 280 EAST
City
OPELIKA
State
AL
ZIP
36804
Mailing
2905 HIGHWAY 280 EAST, OPELIKA, AL 36804
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325188
Employees
11
Ownership type
A

4 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 21, 2017
Abate by
Apr 13, 2017
Penalty
Initial $7,243 · Current $5,000 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  (a) Reactor area - Employees exposed to thermal energy hazards from steam pipes that are not insulated.  The employees are not provided with thermal protection of the extremities and face to protected them from the thermal energy of hot steam pipes.  (b) Reactor area - Employees exposed to thermal energy hazards from steam pipes and jackets that are leaking.  The employees are not provided with thermal protection of the extremities and face to protected them from the steam leaks on the 2000 gallon reactor and the new 4000 gallon reactor.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7243

1910.305 J02 V

Serious Gravity 5 2 instances 1 exposed
Issued
Mar 21, 2017
Abate by
Apr 13, 2017
Penalty
Initial $7,243 · Current $5,000 Reduced
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered.  a)  On October 25, 2016 the electrical outlets in the quality control laboratory that are with-in 16 inches of the water sink were not have an enclosure or protected with a ground fault circuit-interrupter for personnel in accordance with the National Electric Code NFPA 70-1999 Article 210-8.  b)  On October 25, 2016 the electrical outlets in the employee break room that are with-in 29 inches of the water sink were not have an enclosure or protected with a ground fault circuit-interrupter for personnel in accordance with the National Electric Code NFPA 70-1999 Article 210-8.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7243

1910.303 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 21, 2017
Abate by
Apr 13, 2017
Penalty
Initial $7,243 · Current $3,470 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a)  On October 25, 2016 the electrical panel containing circuit breakers in the office space adjacent to the quality control laboratory area was obstructed with an office desk located in front of the panel.
Recent events (2)
  • — I (S) $3470
  • — Z (S) $7243

1910.305 J02 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 21, 2017
Abate by
Apr 13, 2017
Penalty
Initial $9,054 · Current $5,000 Reduced
29 CFR 1910.305(j)(2)(vii): A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use did not have an enclosure that was weatherproof when the attachment plug cap was removed:  (a)  Reactors Area - The 120 volt electric outlet box between the new 4000 gallon reactor and the 5000 gallon reactor is not approved for the location due to water coming down from the mezzanine area.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9054