Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PAR METAL PRODUCTS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PAR METAL PRODUCTS, INC. in 21 EWING AVE., NORTH ARLINGTON, NJ 07031 (NAICS 332312). OSHA activity number 341864403.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PAR Metal Products, INC. — free Get an email when a new federal OSHA severe-injury report for PAR Metal Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
21 EWING AVE.
City
NORTH ARLINGTON
State
NJ
ZIP
07031
Mailing
21 EWING AVE., NORTH ARLINGTON, NJ 07031
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
15
Ownership type
A

10 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 11 exposed
Issued
Apr 7, 2017
Abate by
May 24, 2017
Penalty
Initial $4,563 · Current $0 Reduced
OSH Act of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely cause death or serious physical harm to employees in that employees were exposed to combustible aluminum metal dust deflagration, explosion, and other fire hazards while working at or near Shop Fox Model W1666/W1685 dust collection system that was not designed and located to prevent or minimize employee exposure in the event of an internal deflagration or other fire event:   a)       Front Warehouse: On or about, 10/24/2016 employees were exposed to combustible aluminum metal dust deflagration, explosion, and other fire hazards. A Shop Fox dust collector Model W1666/W1685 specifically designed to collect wood dust was utilized to collect aluminum metal dust. The system was not designed and located to prevent or minimize employee exposure in the event of an internal deflagration or other fire event.
Recent events (3)
  • — F (S) $0
  • — C (S) $4563
  • — Z (S) $4563

1910.107 C06

Deleted Serious Gravity 10 2 instances 1 exposed
Issued
Apr 7, 2017
Abate by
May 24, 2017
Penalty
Initial $4,563 · Current $0 Reduced
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for     Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:  a) Spray Booth: Employees were exposed to explosion and fire hazards from an electrical light fixture that was not explosion proof , on or about 10/24/2016.
Recent events (3)
  • — F (S) $0
  • — C (S) $4563
  • — Z (S) $4563

1910.176 C

Deleted Serious Gravity 10 2 instances 11 exposed
Issued
Apr 7, 2017
Abate by
May 24, 2017
Penalty
Initial $4,563 · Current $0 Reduced
29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage:  a) Front Warehouse: Employees were exposed to tripping, fire, and explosion hazards from improper storage of materials, on or about 10/24/2016.  b) Warehouse: Employees were exposed to tripping, fire, and explosion hazards from improper storage of materials, on or about 10/24/2016.
Recent events (3)
  • — F (S) $0
  • — C (S) $4563
  • — Z (S) $4563

1910.213 D01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Apr 7, 2017
Abate by
May 24, 2017
Penalty
Initial $4,563 · Current $0 Reduced
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  a) Warehouse: Employees were exposed to amputation hazard from a table saw that did not have a guard installed, on or about 10/24/2016.
Recent events (3)
  • — F (S) $0
  • — C (S) $4563
  • — Z (S) $4563

1910.253 B02 II

Deleted Serious Gravity 5 1 instance 11 exposed
Issued
Apr 7, 2017
Abate by
May 24, 2017
Penalty
Initial $3,911 · Current $0 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  a) Front Warehouse: Employees were exposed to fire and struck by hazards from acetylene cylinders and propane cylinders that could be knocked over by passing people or objects, on or about 10/24/2016.
Recent events (3)
  • — F (S) $0
  • — C (S) $3911
  • — Z (S) $3911

1910.253 B02 IV

Deleted Serious Gravity 5 1 instance 11 exposed
Issued
Apr 7, 2017
Abate by
May 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  a) Front Warehouse: Employees were exposed to explosion and fire hazards from acetylene gas cylinders that did not have valve protection cap in place, on or about 10/24/2016.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 G01

Deleted Serious Gravity 10 1 instance 11 exposed
Issued
Apr 7, 2017
Abate by
May 24, 2017
Penalty
Initial $4,563 · Current $0 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) Front Warehouse: Employees were exposed to electrocution hazard from electrical panels that were blocked by storage, on or about 10/24/2016.
Recent events (3)
  • — F (S) $0
  • — C (S) $4563
  • — Z (S) $4563

1910.305 A02 IX

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Apr 7, 2017
Abate by
May 24, 2017
Penalty
Initial $3,911 · Current $0 Reduced
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded.  a) Spray Booth: Employees were exposed to shock hazards from fluorescent bulbs in a light fixture that were not guarded to protect from accidental breakage, on or about 10/24/2016.  b) Grinding Room: Employees were exposed to shock hazards from fluorescent bulbs in a light fixture that were not guarded to protect from accidental breakage, on or about 10/24/2016.
Recent events (3)
  • — F (S) $0
  • — C (S) $3911
  • — Z (S) $3911

1910.305 A02 XI

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Apr 7, 2017
Abate by
May 24, 2017
Penalty
Initial $3,911 · Current $0 Reduced
29 CFR 1910.305(a)(2)(xi): Cable assemblies and flexible cords and cables were not supported in place at intervals that ensure that they will be protected from physical damage:   a) Dip Tank Room: Employee was exposed to shock hazards from flexible cables that were not properly supported to prevent physical damage, on or about 10/24/2016.
Recent events (3)
  • — F (S) $0
  • — C (S) $3911
  • — Z (S) $3911

1910.305 G01 IV A

Deleted Serious Gravity 5 1 instance 11 exposed
Issued
Apr 7, 2017
Abate by
May 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Warehouse: Employees were exposed to shock hazard from flexible cords used a substitute for fixed wiring, on or about 10/24/2016.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View PAR Metal Products, INC.'s full OSHA safety record →