SHAW A F B, SC —
OSHA Inspection: CULLUM CONSTRUCTORS. INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CULLUM CONSTRUCTORS. INC. in 524 SHAW DRIVE, SHAW A F B, SC 29152 (NAICS 238220). OSHA activity number 341864809.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CULLUM CONSTRUCTORS. INC.
- Site address
- 524 SHAW DRIVE
- City
- SHAW A F B
- State
- SC
- ZIP
- 29152
- Mailing
- PO BOX 40368, CHARLESTON, SC 29423
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.404 F06
- Issued
- Nov 23, 2016
- Penalty
- Initial $3,680 · Current $2,208 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Northwest corner of Basement Area A: A Schaefer pedestal fan used by the employees for ventilation did not have a continuous grounding path due to a two-prong replacement plug-end that was attached on the end of the three-wired cord, thus negating the grounding conductor.
Recent events (2)
- — I (S) $2208
- — Z (S) $3680
1926.404 A02
- Issued
- Nov 23, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(a)(2): A grounded conductor was attached to a terminal or lead so as to reverse designated polarity: a) 1st floor Area C: An extension cord used at the worksite to operate power tools was found to have reversed polarity.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Cullum Constructors. INC.
View Cullum Constructors. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in SC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341864809.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.