OSHA Inspection: K-MAC ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of K-MAC ROOFING in 5324 ENCHANTED DR., WELDON SPRING, MO 63304 (NAICS 238160). OSHA activity number 341865038.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch K-Mac Roofing — free Get an email when a new federal OSHA severe-injury report for K-Mac Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
K-MAC ROOFING
Site address
5324 ENCHANTED DR.
City
WELDON SPRING
State
MO
ZIP
63304
Mailing
920 BENT OAK CT, COURTSUITE H, LAKE SAINT LOUIS, MO 63367
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Repeat Gravity 5 1 instance 4 exposed
Issued
Nov 9, 2016
Penalty
Initial $5,345 · Current $2,673 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems:     On 10/25/2016, employees for K-Mac Roofing were working on the roof of a residential structure located at 5324 Enchanted Dr., Weldon Spring, MO.  The employees were observed on the roof of the residence without fall protection, exposing them to fall hazard.    The K-Mac Roofing was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 464978, citation number 1, item number 2, and was affirmed as a final order on 07/05/2012, with respect to a workplace located at 3722 Av De Paris Drive, Florissant, MO 63034.
Recent events (2)
  • — I (R) $2673
  • — Z (R) $5345

1926.1053 B01

Repeat Gravity 5 1 instance 4 exposed
Issued
Nov 9, 2016
Penalty
Initial $4,276 · Current $2,138 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:     On 10/25/2016, employees for K-Mac Roofing were working on the roof of a residential structure located at 5324 Enchanted Dr., Weldon Spring, MO.  They were utilizing an extension ladder for access to the upper roof level.  This ladder did not extent at least 3 feet above the upper level.     The K-Mac Roofing was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 464978, citation number 1, item number 3, and was affirmed as a final order on 07/05/2012, with respect to a workplace located at 3722 Av De Paris Drive, Florissant, MO 63034.