Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALTERNATIVE ROOFING SOLUTIONS, INC. in 800 SHAW DRIVE, SHAW A F B, SC 29152 (NAICS 238160). OSHA activity number 341865186.

Watch Alternative Roofing Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for Alternative Roofing Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
800 SHAW DRIVE
City
SHAW A F B
State
SC
ZIP
29152
Mailing
326 BROWN'S COVE ROAD, RIDGELAND, SC 29936
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $7857.00 · Current $4321.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    a) Lower roof of Gym building. Employees engaged in roofing activities were not protected from falling approximately 14 feet to the ground below.
Recent events (2)
  • — I (S) $4321
  • — Z (S) $7857

1926.503 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3367.00 · Current $1852.00 Reduced
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record:    a)  Worksite: The employer could not provide a list of names or any other documents that verify that individual employees had received the training required.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $1852
  • — Z (S) $3367

1926.503 C

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(c): The employer did not retrain affected employees  who already had been trained but demonstrated inadequate  understanding and skill required by paragraph (a) of this section:  a) Worksite: Employees working on the roof of the building had shown a need for retraining in fall hazards as evidenced by: Not using safety harnesses and lifelines when needed, not having flagged off the  area or access points.  ABATEMENT CERIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B08

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $4489.00 · Current $2469.00 Reduced
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities away from the ladder.     a) North side of the building at the lower roof edge: The ladder used by employees to access the roof was placed in an area between two doorways which was frequented by foot and vehicular traffic, was not secured from movement.
Recent events (2)
  • — I (S) $2469
  • — Z (S) $4489

1926.1060 B

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1060(b): The employer did not provide retraining as necessary for each employee using ladders and stairways so that the employee maintained the understanding and knowledge acquired through prior training:  a) North side of the building at the lower roof edge: Employees showed that they had not retained the training they had been given on ladder safety as evidenced by having placed the ladder directly into the dirt, having no flagging at the upper access point, not securing it from movement, and placing a rope and anchor on it in such a way that it appeared to be tied off to prevent movement or displacement.   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 F01 III

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines:  a) North end of the building center of the lower roof: The point of access to the roof was not equipped with two warning lines from the exit point of the extension ladder to the work area.
Recent events (2)