COLORADO SPRINGS, CO —
OSHA Inspection: LHM COLLISION CORPORATION - CSCO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LHM COLLISION CORPORATION - CSCO in 5595 N. ACADEMY BLVD., COLORADO SPRINGS, CO 80918 (NAICS 811121). OSHA activity number 341865681.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LHM COLLISION CORPORATION - CSCO
- Site address
- 5595 N. ACADEMY BLVD.
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80918
- Mailing
- 5595 N. ACADEMY BLVD., COLORADO SPRINGS, CO 80918
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 23
- Ownership type
- A
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $2,850 · Current $1,500 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and struck-by hazards while using an automotive lift: (a) On or about October 19, 2016, and at times prior, the employer did not ensure that employees were safe from crushing and struck-by hazards while using the 12,000 pound capacity Rotary Lift, Model SP012N510, in that the lifting pads on the swing arms did not contact the frame of Toyota Highlanders at the pinch welds that Toyota specified for lifting Highlanders, even with the manufactured riser attachments provided by the lift manufacture. Toyota Highlanders were raised with unrated, unlisted and uncertified wooden blocks placed on the lifting pads of the swing arms. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1500
- — Z (S) $2850
1910.110 B06 I
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $2,138 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.110(b)(6)(i): Containers and first stage regulating equipment of liquid petroleum gases were not located outside of the building: (a) On or about October 19, 2016, and at times prior, employees were exposed to explosion and fire hazards from a propane tank that was stored inside in the storage area south of the east body shop. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1100
- — Z (S) $2138
1910.253 B04 III
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: (a) On or about October 19, 2016, and at times prior, employees were exposed to explosion and fire hazards in the storage area south of the east body shop, from the oxygen and acetylene tanks that were stored together. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $2,850 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about October 19, 2016, and at times prior, the employer did not ensure that employees were safe while using respirators in paint booths, in the paint mixing room, and during paint preparation and other sanding activities, in that the establishment has not fully implement its respiratory protection program. The program is a template that has not been adequately tailored for operations at this establishment. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1400
- — Z (S) $2850
1910.134 G01 I A
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) On or about October 19, 2016, and at times prior, employees who were required to wear tight-fitting respirators in the painting area had facial hair between the skin and seal of the tight fitting respirator. Abatement Note: Abatement certification and documentation required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (a) On or about October 19, 2016, and at times prior, employees were exposed to contaminates while wearing respirators that had not been stored in sealed bags. Respirators were stored in drawers and cabinets that were not air tight in the work area. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $2,138 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:(a) (a) On or about October 19, 2016, and at times prior, employees were not protected from flying chips and other hazards while dusting themselves with compressed air that was measured to be greater than 100 p.s.i. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1100
- — Z (S) $2138
1910.303 G01
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $2,138 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about October 19, 2016, and at times prior, employees were exposed to fire, smoke inhalation, and electrical hazards from cardboard and other items stored in front of electrical equipment in the electrical room on the south side of the building, and in front of electrical panels on the south wall of the storage area. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1100
- — Z (S) $2138
1910.304 G05
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $2,138 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: (a) On or about October 19, 2016, and at times prior, employees were exposed to shock and electrical hazards from an electric battery charger with a missing grounding prong on the power cord, in the west body shop. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1000
- — Z (S) $2138
1910.334 A02 II
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: (a) On or about October 19, 2016, and at times prior, employees were exposed to electrical and fire hazards in that the insulation of an extension cord that the employee connected to a battery charger located next to the west wall of the body room, was cut and broken. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 A
- Issued
- Jan 10, 2017
- Abate by
- Jan 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: (a) On or about October 19, 2016, and at times prior, the employer did not inspect employee owned equipment to ensure it was safe before allowing its use in the workplace. An employee owned battery charger had a missing grounding prong. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").