Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRADEN SHIELDING SYSTEMS, L.L.C.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRADEN SHIELDING SYSTEMS, L.L.C. in 9260 BROKEN ARROW EXPRESSWAY, TULSA, OK 74145 (NAICS 337127). OSHA activity number 341869691.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Braden Shielding Systems, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Braden Shielding Systems, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
9260 BROKEN ARROW EXPRESSWAY
City
TULSA
State
OK
ZIP
74145
Mailing
9260 BROKEN ARROW EXPRESSWAY, TULSA, OK 74145
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337127
Employees
24
Ownership type
A

6 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 6, 2017
Abate by
Feb 22, 2017
Penalty
Initial $2,463 · Current $1,478 Reduced
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained.  On or about October 26, 2016, there were no operable gauges or alarms in the paint spray booth to indicate or ensure that the required air speed was maintained.  Employees were exposed to respiratory hazards and/or hazards associated with fire and explosion.
Recent events (2)
  • — I (S) $1477.8
  • — Z (S) $2463

1910.107 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 6, 2017
Abate by
Feb 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.107(c)(2): Open flame or spark producing equipment was located in the spraying area or within 20 feet thereof, and was not separated by a partition.  On or about October 26, 2016, an electrical outlet was located within 20 feet of the paint spray booth and was not separated by a partition.  Employees were exposed to the hazard of fire and/or explosion.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 6, 2017
Abate by
Feb 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:  On or about October 26,2016, paint spray booth was not kept free from the accumulation of deposits of combustible residues.  Employees were exposed to the hazard of fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 6, 2017
Abate by
Feb 22, 2017
Penalty
Initial $2,463 · Current $1,478 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  On or about October 26, 2016, the employer did not provide a medical evaluation to determine employee's ability to use a respirator before requiring employee to use a tight-fitting half facepiece respirator.  Employee was exposed to respiratory hazards.
Recent events (2)
  • — I (S) $1477.8
  • — Z (S) $2463

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 6, 2017
Abate by
Feb 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:   On or about October 26, 2016, the employer did not provide fit testing for employees using tight-fitting half facepiece respirators prior to use.  Employees were exposed respiratory hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 9 exposed
Issued
Feb 6, 2017
Abate by
Feb 22, 2017
Penalty
Initial $2,463 · Current $1,478 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  On or about October 26, 2016, the employer did not develop, implement and maintain a written hazard communication program that described how the criteria for labeling, safety data sheets, and training would be met.  Employees were using products that contained chemicals such as, but not limited to; Toluene at 30-50%, n-Butyl alcohol at 10-30%, and Acetone at 20-30%.  Employees were exposed to respiratory hazards and/or hazards associated with fire/explosion.
Recent events (2)
  • — I (S) $1477.8
  • — Z (S) $2463

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341869691.