Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: THE GATEWAY COMPANY OF MISSOURI

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE GATEWAY COMPANY OF MISSOURI in 6425 GRAHAM RD., SAINT LOUIS, MO 63134 (NAICS 332312). OSHA activity number 341869956.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Gateway Company of Missouri for free Get an email when a new federal OSHA severe-injury report for The Gateway Company of Missouri is published. One employer, no account, unsubscribe in one click.
Site address
6425 GRAHAM RD.
City
SAINT LOUIS
State
MO
ZIP
63134
Mailing
6425 GRAHAM RD., SAINT LOUIS, MO 63134
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
20
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C04 I

Other-than-serious 1 instance 1 exposed
Issued
Nov 17, 2016
Abate by
Dec 14, 2016
Penalty
Initial $3,563 · Current $2,494 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance:     On 10/27/16, The Gateway Company of Missouri, located at 6425 Graham Road, St. Louis, MO, had not developed, documented and utilized proper procedures for the control of potentially hazardous energy for the Cincinnati 500 Shear located in the NW quadrant of Building #2.
Recent events (2)
  • · I (O) $2494.1
  • · Z (S) $3563

1910.178 P01

Other-than-serious 1 instance 1 exposed
Issued
Nov 17, 2016
Abate by
Dec 14, 2016
Penalty
Initial $2,850 · Current $1,995 Reduced
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition:     On 10/27/2016, The Gateway Company of Missouri, located at 6425 Graham Road, St. Louis, MO, employee(s) were exposed to a forklift in need of repair.  The locator/index pin was missing on the Komatsu forklift (Model: FG40Z, S/N: 102797).  This forklift was mainly operated in the Paint Department building
Recent events (2)
  • · I (O) $1995
  • · Z (S) $2850

1910.179 G01 V

Other-than-serious 1 instance 1 exposed
Issued
Nov 17, 2016
Abate by
Dec 14, 2016
Penalty
Initial $2,850 · Current $1,995 Reduced
29 CFR 1910.179(g)(1)(v): Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions:     On 10/27/2016, The Gateway Company of Missouri, located at 6425 Graham Road, St. Louis, MO, crane operator(s) had the cranes pendant missing the labeling on the controller.  The unlabeled pendant buttons controlled the direction of the hoist during its operation.  The was observed on the West Landel, Inc. crane in Building #2 the Fab Shop.
Recent events (2)
  • · I (O) $1995
  • · Z (S) $2850

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341869956.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.