MCKINNEY, TX —
OSHA Inspection: DAVIS CABLE TECHNOLOGIES, L.P.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of DAVIS CABLE TECHNOLOGIES, L.P. in FM 1461, MCKINNEY, TX 75071 (NAICS 517919). OSHA activity number 341870020.
Where did this inspection happen?
- Establishment
- DAVIS CABLE TECHNOLOGIES, L.P.
- Site address
- FM 1461
- City
- MCKINNEY
- State
- TX
- ZIP
- 75071
- Mailing
- 6632 CR 1022, JOSHUA, TX 76058
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 517919
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.268 B07
- Issued
- Abate by
- Penalty
- Initial $12675.00 · Current $8238.00 Reduced
General-duty citation text
29 CFR 1910.268(b)(7): The employer did not ensure that no employee approached or took any conductive object closer to any electrically energized overhead power lines and parts than prescribed in Table R-2 or in (i) - (iii) of this section: (a) On or about October 25, 2016, on the east side of FM 1461, the employer did not ensure an employee installing telecommunications strand maintained a minimum approach distance to an energized overhead power line with a phase-to-phase voltage of approximately 24.9 kV.
Recent events (2)
- — I (S) $8238
- — Z (S) $12675
1910.268 J03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.268(j)(3): Vehicle-mounted elevating and rotating work platforms were operated with a conductive part of the equipment closer to exposed energized power lines than the clearances set forth in Table R-2 of this section: (a) On or about October 25, 2016, on the east side of FM 1461, an employee installing telecommunications strand operated a non-insulated, truck-mounted, articulating telescopic aerial lift closer than the minimum approach distance prescribed for an energized overhead power line with a phase-to phase voltage of approximately 24.9 kV.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.268 C
- Issued
- Abate by
- Penalty
- Initial $5070.00 · Current $3291.00 Reduced
General-duty citation text
29 CFR 1910.268(c): The employer did not provide training in the various precautions and safe practices described in this section and did not ensure that employees did not engage in the activities to which this section applies until such employees have received proper training in the various precautions and safe practices required by this section: (a) On or about October 25, 2016, on the east side of FM 1461, employees installing telecommunications strand had not been provided training in the precautions and safe practices described in 1910.268.
Recent events (2)
- — I (S) $3291
- — Z (S) $5070
1910.268 C03
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $2354.00 Reduced
General-duty citation text
29 CFR 1910.268(c)(3): Training provided by the employer did not include first aid training, including instruction in artificial respiration: (a) On or about October 25, 2016, on the east side of FM 1461, employees installing telecommunications strand had not been provided first aid training, including instruction in artificial respiration.
Recent events (2)
- — I (S) $2354
- — Z (S) $3622
1910.268 I02
- Issued
- Abate by
- Penalty
- Initial $2897.00 · Current $1883.00 Reduced
General-duty citation text
29 CFR 1910.268(i)(2): Eye protection meeting the requirements was not provided and/or the employer did not ensure its use by employees where foreign objects may enter the eyes due to work operations: (a) On or about October 25, 2016, on the east side of FM 1461, the employer did not provide and require employees to use eye protection that met the requirements of 1910.133 during tree pruning operations.
Recent events (2)
- — I (S) $1883
- — Z (S) $2897
1910.268 N01 I
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $2354.00 Reduced
General-duty citation text
29 CFR 1910.268(n)(1)(i): The employer did not ensure that employees wore insulating gloves and/or did not avoid body contact when handling cable suspension strand being installed on poles carrying exposed energized power conductors: (a) On or about October 25, 2016, on the east side of FM 1461, the employer did not ensure an employee wore insulating gloves while installing telecommunications strand on poles carrying energized conductors with phase-to-ground voltages of approximately 14.4 kV.
Recent events (2)
- — I (S) $2354
- — Z (S) $3622
More inspections in this industry (NAICS 517919)
DORCHESTER, MA—2026-06-24
VERIZON
MECHANICSBURG, PA—2026-06-04
RJL COMMUNICATIONS, LLC
MENASHA, WI—2026-06-03
ALVARADO TELECOM LLC
OLD HICKORY, TN—2026-06-03
SOURCE BROADBAND SERVICES, LLC
PORTAGE, MI—2026-05-26
TOWNSQUARE MEDIA KALAMAZOO, LLC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341870020.