Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAVIS CABLE TECHNOLOGIES, L.P.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of DAVIS CABLE TECHNOLOGIES, L.P. in FM 1461, MCKINNEY, TX 75071 (NAICS 517919). OSHA activity number 341870020.

Watch Davis Cable Technologies, L.P. — free Get an email when a new federal OSHA severe-injury report for Davis Cable Technologies, L.P. is published. One employer, no account, unsubscribe in one click.
Site address
FM 1461
City
MCKINNEY
State
TX
ZIP
75071
Mailing
6632 CR 1022, JOSHUA, TX 76058
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
517919
Employees
3
Ownership type
A

6 citations on file for this inspection.

1910.268 B07

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $12675.00 · Current $8238.00 Reduced
29 CFR 1910.268(b)(7): The employer did not ensure that no employee approached or took any conductive object closer to any electrically energized overhead power lines and parts than prescribed in Table R-2 or in (i) - (iii) of this section:    (a) On or about October 25, 2016, on the east side of FM 1461, the employer did not ensure an employee installing telecommunications strand maintained a minimum approach distance to an energized overhead power line with a phase-to-phase voltage of approximately 24.9 kV.
Recent events (2)
  • — I (S) $8238
  • — Z (S) $12675

1910.268 J03

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.268(j)(3): Vehicle-mounted elevating and rotating work platforms were operated with a conductive part of the equipment closer to exposed energized power lines than the clearances set forth in Table R-2 of this section:  (a) On or about October 25, 2016, on the east side of FM 1461, an employee installing telecommunications strand operated a non-insulated, truck-mounted, articulating telescopic aerial lift closer than the minimum approach distance prescribed for an energized overhead power line with a phase-to phase voltage of approximately 24.9 kV.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.268 C

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $3291.00 Reduced
29 CFR 1910.268(c): The employer did not provide training in the various precautions and safe practices described in this section and did not ensure that employees did not engage in the activities to which this section applies until such employees have received proper training in the various precautions and safe practices required by this section:    (a) On or about October 25, 2016, on the east side of FM 1461, employees installing telecommunications strand had not been provided training in the precautions and safe practices described in 1910.268.
Recent events (2)
  • — I (S) $3291
  • — Z (S) $5070

1910.268 C03

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $2354.00 Reduced
29 CFR 1910.268(c)(3): Training provided by the employer did not include first aid training, including instruction in artificial respiration:    (a) On or about October 25, 2016, on the east side of FM 1461, employees installing telecommunications strand had not been provided first aid training, including instruction in artificial respiration.
Recent events (2)
  • — I (S) $2354
  • — Z (S) $3622

1910.268 I02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2897.00 · Current $1883.00 Reduced
29 CFR 1910.268(i)(2): Eye protection meeting the requirements was not provided and/or the employer did not ensure its use by employees where foreign objects may enter the eyes due to work operations:    (a) On or about October 25, 2016, on the east side of FM 1461, the employer did not provide and require employees to use eye protection that met the requirements of 1910.133 during tree pruning operations.
Recent events (2)
  • — I (S) $1883
  • — Z (S) $2897

1910.268 N01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $2354.00 Reduced
29 CFR 1910.268(n)(1)(i): The employer did not ensure that employees wore insulating gloves and/or did not avoid body contact when handling cable suspension strand being installed on poles carrying exposed energized power conductors:    (a) On or about October 25, 2016, on the east side of FM 1461, the employer did not ensure an employee wore insulating gloves while installing telecommunications strand on poles carrying energized conductors with phase-to-ground voltages of approximately 14.4 kV.
Recent events (2)
  • — I (S) $2354
  • — Z (S) $3622

VERIZON

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341870020.