Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: OLIVER CHAVEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OLIVER CHAVEZ in 67 MCMULLEN LANE, GURLEY, AL 35748 (NAICS 238130). OSHA activity number 341870418.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oliver Chavez for free Get an email when a new federal OSHA severe-injury report for Oliver Chavez is published. One employer, no account, unsubscribe in one click.
Establishment
OLIVER CHAVEZ
Site address
67 MCMULLEN LANE
City
GURLEY
State
AL
ZIP
35748
Mailing
777 HIGHWAY 231, LACEYS SPRING, AL 35754
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
Private (A)

6 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 22, 2016
Penalty
Initial $1,604 · Current $962 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) On or about 10/25/2016 - 67 McMullen Lane, Gurley, AL, employees working on the ground handing up cut pieces of plywood were not provided hard hats.
Recent events (2)
  • · I (S) $962.4
  • · Z (S) $1604

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 22, 2016
Penalty
Initial $1,604 · Current $962 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    a) On or about 10/25/2016 - 67 McMullen Lane, Gurley, AL, employees operating nail guns and skilsaws to install and cut plywood were not wearing safety glasses.
Recent events (2)
  • · I (S) $962.4
  • · Z (S) $1604

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 22, 2016
Penalty
Initial $3,741 · Current $2,245 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     a) On or about 10/25/2016 - 67 McMullen Lane, Gurley, AL, employees working on a steep-sloped rafter and decking system constructed on a (12:12) pitch were not protected from falls of approximately 13 feet to the ground.
Recent events (2)
  • · I (S) $2244.6
  • · Z (S) $3741

1926.503 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 22, 2016
Abate by
Dec 5, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) On or about 10/25/2016 - 67 McMullen Lane, Gurley, AL, employees installing plywood decking at approximately 13 feet above the ground on a (12:12) steep-sloped decking and rafter system were unaware of fall hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 22, 2016
Penalty
Initial $2,672 · Current $1,603 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) On or about 10/25/2016 - 67 McMullen Lane, Gurley, AL, employees installing plywood on the rafter and decking systems were using an extension ladder that was not extended 3 feet or more above the landing surface.
Recent events (2)
  • · I (S) $1603.2
  • · Z (S) $2672

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
Nov 22, 2016
Abate by
Dec 5, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  a) On or about 10/25/2016 - 67 McMullen Lane, Gurley, AL, electrical equipment such as skilsaws and reciprocating saws were powered by flexible cords with defective strain relief.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341870418.