SAINT AUGUSTINE, FL —
OSHA Inspection: A TO Z CUSTOM HOMES, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of A TO Z CUSTOM HOMES, INC in 105 SGT TUTTEN DR MANNING BUILDING SUPPLY, SAINT AUGUSTINE, FL 32086 (NAICS 238160). OSHA activity number 341874576.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A TO Z CUSTOM HOMES, INC
- Site address
- 105 SGT TUTTEN DR MANNING BUILDING SUPPLY
- City
- SAINT AUGUSTINE
- State
- FL
- ZIP
- 32086
- Mailing
- 4925 PORTER ROAD, SAINT AUGUSTINE, FL 32095
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.21 B05
- Issued
- Nov 29, 2016
- Penalty
- Initial $4,988 · Current $3,741 Reduced
General-duty citation text
29 CFR 1926.21(b)(5): Employee(s) required to handle or use flammable liquids, gases, or toxic materials were not instructed in the safe handling and use of these materials and made aware of the specific requirements contained in 29 CFR 1926, subparts D. a. On or about October 28, 2016 employees were applying a combustible silicone roof coating blended with a highly flammable reducer and were not trained by the employer on how to safely handle, and use these products, exposing employees to burn hazards. In the alternative 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s).
Recent events (2)
- — I (S) $3741
- — Z (S) $4988
1926.150 C01 I
- Issued
- Nov 29, 2016
- Penalty
- Initial $2,138 · Current $0 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(i): Travel distance from any point of the protected area to the nearest fire extinguisher exceeded 100 feet. a. On or about October 28, 2016 employer did not ensure an adequate suitable fire extinguisher was near the spraying area where employees were spraying a flammable silicone base roof waterproofing.
Recent events (2)
- — I (O) $0
- — Z (S) $2138
1926.152 E02
- Issued
- Nov 29, 2016
- Penalty
- Initial $4,988 · Current $3,741 Reduced
General-duty citation text
29 CFR 1926.152(e)(2): The transfer of flammable liquids from one container to another was done when the containers were not electrically interconnected (bonded). a. On or about October 28, 2016 employees transferring flammable liquids, like reducer from 1 gallon cans, and silicone paint into a 5 gallon plastic bucket were exposed to static charges and flash fires because the 5 gallon plastic bucket they were using was not grounded or effectively bounded to the gasoline operated paint sprayer or grounded to the earth, to prevent discharge of static electricity.
Recent events (2)
- — I (S) $3741
- — Z (S) $4988
1926.152 I06
- Issued
- Nov 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.152(i)(6): In locations where flammable vapors could have been present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition: a. On or about October 28, 2016 two employees were using combustible residue and explosive vapors in an area directly adjacent to electrical equipment and heat sources.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Nov 29, 2016
- Penalty
- Initial $4,988 · Current $3,741 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a. On or about October 28, 2016 employees had placed a portable A frame fiberglass ladder to gain access to a roof and did not have the top of the ladder extend at least 3 feet above the point of the roofline.
Recent events (2)
- — I (S) $3741
- — Z (S) $4988
1926.1053 B04
- Issued
- Nov 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a. On or about October 28, 2016 employees had placed a fiberglass A Frame ladder against an exterior wall in the folded position to gain access to an upper level. The ladder was not used as designed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at A to Z Custom Homes, INC
View A to Z Custom Homes, INC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341874576.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.