OSHA Inspection: BIG RIVER RESOURCES, LLC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BIG RIVER RESOURCES, LLC. in N10185 370TH STREET, BOYCEVILLE, WI 54725 (NAICS 325193). OSHA activity number 341883973.

Watch BIG River Resources, LLC. — free Get an email when a new federal OSHA severe-injury report for BIG River Resources, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
N10185 370TH STREET
City
BOYCEVILLE
State
WI
ZIP
54725
Mailing
N10185 370TH STREET, BOYCEVILLE, WI 54725
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325193
Employees
37
Ownership type
A

5 citations on file for this inspection.

1910.119 D03 I B

Serious Gravity 1 2 instances 37 exposed
Issued
Abate by
Penalty
Initial $4089.00 · Current $2862.00 Reduced
29 CFR 1910.119(d)(3)(i)(B): The employer's piping and instrument diagrams (P&IDs) were not accurate and did not represent equipment that was existing and was part of the process:  (a) Distillation/Evaporation Rectifier P&ID E245-0704-500; The P&IDs were not accurate and did not represent the fusel line from the TP-4501 Rectifier Column (PD-4505 Fusel Draw Pump) to the TP-4611 200 Proof Flash Vessel (PC-4611 200 Proof Product Pump).  (b) Distillation/Evaporation Molecular Sieves P&ID E245-0704-600; The P&IDs were not accurate and did not represent the fusel line from the TP-4501 Rectifier Column (PD-4505 Fusel Draw Pump) to the TP-4611 200 Proof Flash Vessel (PC-4611 200 Proof Product Pump).
Recent events (2)
  • — I (S) $2862.3
  • — Z (S) $4089

1910.119 L04

Serious Gravity 1 2 instances 37 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.119(l)(4): Process safety information required by paragraph (d) of this section was not updated when a change covered by this paragraph resulted in a change in the process safety information:  (a) Distillation; A Management of Change was not implemented and documented for the addition of a fusel line from the TP-4501 Rectifier Column (PD-4505 Fusel Draw Pump) to the TP-4611 200 Proof Flash Vessel (PC-4611 200 Proof Product Pump).  (b) Distillation; A Management of Change was not implemented and documented for the extended lockout of a line on the EP-4611 Sieve Feed Economizer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 II

Serious Gravity 1 2 instances 37 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not used for lockout and tagout purposes only:  (a) Distillation; Lockout devices were utilized for purposes other than controlling energy, a lockout device was utilized for an extended period of time to lock out the fusel line from the TP-4501 Rectifier Column (PD-4505 Fusel Draw Pump) to the TP-4611 200 Proof Flash Vessel (PC-4611 200 Proof Product Pump).   (b) Distillation; Lockout devices were utilized for purposes other than controlling energy, a lockout device was utilized for an extended period of time to lock out a line on the EP-4611 Sieve Feed Economizer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 J06 II

Other-than-serious 2 instances 37 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.119(j)(6)(ii): Appropriate checks and inspections were not performed to assure that equipment was installed properly and consistent with design specifications and the manufacturer's instructions:  (a) Distillation, Sieve Bottle #1 (TP- 4601); Pressure Indicator (PI4602B) was missing.  (b) Distillation, Sieve Bottle #3 (TP4603); Pressure Indicator (PI4606B) was missing.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I C

Other-than-serious 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:  (a) Throughout the facility; The  periodic inspection did not include a review between the inspector, the authorized employee(s), and the energy control procedure.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BIG RIVER RESOURCES, LLC.'s full OSHA safety record →