JAMAICA, NY —
OSHA Inspection: EMPIRE CONTROL ABATEMENT, INC.
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of EMPIRE CONTROL ABATEMENT, INC. in JFK INTERNATIONAL AIRPORT BUILDING 139, JAMAICA, NY 11430 (NAICS 562910). OSHA activity number 341895282.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EMPIRE CONTROL ABATEMENT, INC.
- Site address
- JFK INTERNATIONAL AIRPORT BUILDING 139
- City
- JAMAICA
- State
- NY
- ZIP
- 11430
- Mailing
- 14-32 123RD STREET, COLLEGE POINT, NY 11356
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562910
- Employees
- 18
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.1200 E01 I
- Issued
- May 3, 2017
- Abate by
- Jun 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet (Construction Reference: 1926.59): (a) On or about November 7, 2016, at job site at JFK International Airport, Building 139, Jamaica, NY 11430 The employer's written hazard communication program, located on page 15 of the company's Health and Safety Plan with Compliance Programs document, did not contain a list of or any reference to hazardous chemicals such as Aramsco Chemsafe 500C particulate encapsulant and Aramsco Chemsafe Gold wetting agent which are used by company employees during asbestos abatement projects. ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (1)
- — Z (O) $0
1910.1200 E02
- Issued
- May 3, 2017
- Abate by
- Jun 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(2): The employer that produced, used, or stored hazardous chemicals at the workplace in such a way that employees of other employer(s) could be exposed did not ensure that the hazard communication program included all of the elements outlined in 29 CFR 1910.1200(e)(2)(i) through 29 CFR 1910.1200(e)(2)(iii)(Construction Reference: 1926.59): (a) On or about November 7, 2016, at job site at JFK International Airport, Building 139, Jamaica, NY 11430 The employer's written hazard communication program, located on page 15 of the company's Health and Safety Plan with Compliance Programs document, did not address how other employers at multi-employer worksites would be informed of the labeling system, safety data sheet access and precautionary measures necessary to protect employees from hazardous chemicals such as Aramsco Chemsafe 500C particulate encapsulant and Aramsco Chemsafe Gold wetting agent which are used by Empire Control Abatement Inc. employees during asbestos abatement projects. ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (1)
- — Z (O) $0
1926.1101 F01 I
- Issued
- May 3, 2017
- Abate by
- May 9, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(f)(1)(i): Employer did not accurately determine the airborne concentrations of asbestos to which employees were exposed: (a) On or about December 1, 2016, at job site at JFK International Airport, Building 139, Jamaica, NY 11430 Pre- and post-calibration of air sampling pumps used for representative daily monitoring of airborne exposure of employees during clean up of asbestos-containing fireproofing debris and overspray, and disposal of contaminated fiberglass batt insulation, was not performed.
Recent events (1)
- — Z (O) $0
More inspections at Empire Control Abatement, INC.
View Empire Control Abatement, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562910)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341895282.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.