ERIE, PA —
OSHA Inspection: SINGLE PLATE ROOFING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SINGLE PLATE ROOFING, LLC in 415 WEST 12TH STREET, ERIE, PA 16501 (NAICS 238160). OSHA activity number 341896009.
Where did this inspection happen?
- Establishment
- SINGLE PLATE ROOFING, LLC
- Site address
- 415 WEST 12TH STREET
- City
- ERIE
- State
- PA
- ZIP
- 16501
- Mailing
- 802 SPARROWS LANE, NORCROSS, GA 30093
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
10 citations on file for this inspection.
1926.404 B01 I
- Issued
- Abate by
- Penalty
- Initial $2850.00 · Current $2850.00
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: A.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, roof of the structure, on or about November 2, 2016 and times prior thereto: Employees were operating electric power tools including, but not limited to, DeWalt DW272 VSR drywall screwdrivers. The power tools were powered via a Power Stroke portable generator. The power tools were not being used in conjunction with ground-fault circuit interrupters or an assured equipment grounding conductor program.
Recent events (2)
- — I (S) $2850
- — Z (S) $2850
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $4988.00 · Current $4988.00
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. A.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, roof of the structure, on or about November 2, 2016 and times prior thereto: Employees were performing roofing activities including, but not limited to, installing a stand in seam roof. Employees who were working outside of the warning line system were not utilizing other means or methods of fall protection, including, but not limited to, guardrail systems, safety net systems, safety monitors and/or personal fall arrest systems. Employees were exposed to a 19-foot and 20.7-foot fall hazard to the ground below.
Recent events (2)
- — I (S) $4988
- — Z (S) $4988
1926.502 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(h)(1): The employer did not did not designate a competent person to monitor the safety of other employees and/or did not ensure that the safety monitor complied with the requirements listed in (h)(1)(i) through (h)(1)(v) of this section: A.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, roof of the structure, on or about November 2, 2016 and times prior thereto: Employees were performing roofing activities including, but not limited to, installing a stand in seam roof. The safety monitor for the roofing activities was engaged in roofing activities, and was not within visual sight of the employees being monitored, nor close enough to communicate orally with the employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 F02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface. A.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, roof of the structure, north side, on or about November 2, 2016 and times prior thereto: Employees were performing roofing activities including, but not limited to, installing a stand in seam roof. The warning line system was sagging onto the surface of the roof. Employees were exposed to a 20.7-foot fall hazard to the ground below.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 F01 III
- Issued
- Abate by
- Penalty
- Initial $4988.00 · Current $4988.00
General-duty citation text
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines: A.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, east side of the structure, on or about November 2, 2016 and times prior thereto: Employees were performing roofing activities including, but not limited to, installing a stand in seam roof. Employees were utilizing a warning line system that was not erected with an access path formed by two warning lines from the ladder to the warning line system area. B.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, east side of the structure, on or about November 2, 2016 and times prior thereto: Employees were performing roofing activities including, but not limited to, installing a stand in seam roof. Employees were utilizing a warning line system that was not erected with an access path formed by two warning lines from the material landing area to the warning line system area.
Recent events (2)
- — I (S) $4988
- — Z (S) $4988
1926.502 F01 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(f)(1)(iv): When the path to the point of access was not in use, a rope, wire, chain, or other barricade, equivalent in strength and height to the warning line, was not placed across the path at the point where the path intersected the warning line erected around the work area, or the path was not offset such that a person could not walk directly into the work area. A.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, east side of the structure, on or about November 2, 2016 and times prior thereto: Employees were performing roofing activities including, but not limited to, installing a stand in seam roof. Employees were utilizing a warning line system that was not designed with a path to be offset from the ladder to the work area. In addition, the warning line system was not equipped with a rope, wire, chain, or other barricade, equivalent in strength and height to the warning line at the warning line system access point from the ladder area to work area. B.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, east side of the structure, on or about November 2, 2016 and times prior thereto: Employees were performing roofing activities including, but not limited to, installing a stand in seam roof. Employees were utilizing a warning line system that was not designed with a path to be offset from the material landing area and the work area. In addition, the warning line system was not equipped with a rope, wire, chain, or other barricade, equivalent in strength and height to the warning line at the warning line system access point from the material landing area to work area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 F01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge: A.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, roof of the structure, on or about November 2, 2016 and times prior thereto: Employees were performing roofing activities including, but not limited to, installing a stand in seam roof. The warning line system was erected 5-feet from the edge of the roof.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): A.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, on or about November 2, 2016 and times prior thereto: Employees operate forklifts that include, but are not limited to, a SkyJack VR843E rough terrain forklift truck. The employer did not certify the employee's forklift truck training and evaluation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury: A.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, on or about November 2, 2016 and times prior thereto: Employees were provided with, and permitted to use the fire extinguishers on-site. Employees did not have fire extinguisher training. B.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, on or about November 2, 2016 and times prior thereto: Employees were provided with and utilizing personal protective equipment including, but not limited to, safety eyewear and head protection. Employees did not have personal protective equipment training. C.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, on or about November 2, 2016 and times prior thereto: Employees were working with and around electrical equipment including, but not limited to, a portable generator and power tools. Employees did not have electrical safety training.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. A.) Single Plate Roofing, LLC, 415 West 12th Street, Erie, PA 16501, on or about November 2, 2016 and times prior thereto: Employees conducting roofing work were exposed to a fall hazard of 19-feet and 20.7-feet. The employer did not maintain certifications of fall protection training.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341896009.