OSHA Inspection: FAIR AUTO SUPPLY OF NEWTOWN, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FAIR AUTO SUPPLY OF NEWTOWN, INC. in 111 S MAIN ST., NEWTOWN, CT 06470 (NAICS 441310). OSHA activity number 341896686.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fair Auto Supply of Newtown, INC. — free Get an email when a new federal OSHA severe-injury report for Fair Auto Supply of Newtown, INC. is published. One employer, no account, unsubscribe in one click.
Site address
111 S MAIN ST.
City
NEWTOWN
State
CT
ZIP
06470
Mailing
111 S MAIN ST., NEWTOWN, CT 06470
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
Employees
5
Ownership type
A

11 citations on file for this inspection.

1910.36 G02

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 9, 2017
Abate by
Mar 21, 2017
Penalty
Initial $2,716 · Current $1,920 Reduced
29 CFR 1910.36(g)(2): An exit route must meet minimum height and width requirements.  An exit access must be at least 28 inches (71.1 cm) wide at all points. Where there is only one exit access leading to an exit or exit discharge, the width of the exit and exit discharge must be at least equal to the width of the exit access.    ESTABLISHMENT:  The two (2) main exit routes in the basement were not maintained at least 28 inches wide at all points.
Recent events (2)
  • — I (S) $1920
  • — Z (S) $2716

1910.37 A03

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route.   ESTABLISHMENT:  The east and north emergency exit routes in the basement were obstructed with boxes, hose and/or lift jack.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $2,173 · Current $1,500 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    ESTABLISHMENT:  The employer had not conducted a Workplace Hazard Assessment to determine necessitate and appropriate types of personal protective equipment (PPE) for employees.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2173

1910.132 F01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment:  ESTABLISHMENT:  The employees required to wear personal protective equipment (PPE) were not trained in the Workplace Hazard Assessment pertaining to the use and maintenance of the personal protective equipment (PPE).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 D01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 9, 2017
Abate by
Mar 21, 2017
Penalty
Initial $1,630 · Current $1,120 Reduced
29 CFR 1910.141(d)(1): Washing facilities were not maintained in a sanitary condition:    ESTABLISHMENT:  The sink, located outside the bathroom and used for washing was not maintained in a sanitary condition.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1630

1910.141 D02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 9, 2017
Abate by
Mar 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water:  ESTABLISHMENT:  The faucet of the washing sink located outside the bathroom was not provided with hot or tepid running water.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $2,716 · Current $1,920 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    ESTABLISHMENT:  The employer did not ensure through performing training and evaluation that the operator of the Buda forklift powered industrial truck (PIT) was competent to operate the PIT safely at all times..
Recent events (2)
  • — I (S) $1920
  • — Z (S) $2716

1910.253 B02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 9, 2017
Abate by
Mar 21, 2017
Penalty
Initial $2,716 · Current $1,920 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not located where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:    ESTABLISHMENT:  A compressed acetylene gas cylinder was stored in a main aisle and subjected to being knocked over and/or damaged.
Recent events (2)
  • — I (S) $1920
  • — Z (S) $2716

1910.253 B02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 9, 2017
Abate by
Mar 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  ESTABLISHMENT:  The compressed acetylene gas cylinder, that was stored in a main aisle was missing a valve protection cap.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $1,630 · Current $1,120 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    ESTABLISHMENT:  The employer did not develop and implement a written Hazard Communication program, including GHS where employees were required to work with and handle hazardous chemicals, such as (but not limited to) diesel exhaust fuel, hydraulic oil, antifreeze, and car battery fluids.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1630

1910.1200 H01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  ESTABLISHMENT:  The employer did provide information and training on Hazard Communication to the employees who were required to work with and handle hazardous chemicals, such as (but not limited to) diesel exhaust fuel, hydraulic oil, antifreeze, and car battery fluids.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341896686.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.