NEW SMYRNA BEACH, FL —
OSHA Inspection: CLAY WARRENS ROOFING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CLAY WARRENS ROOFING, LLC in 206 DOUGLAS STREET, NEW SMYRNA BEACH, FL 32170 (NAICS 238160). OSHA activity number 341898435.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLAY WARRENS ROOFING, LLC
- Site address
- 206 DOUGLAS STREET
- City
- NEW SMYRNA BEACH
- State
- FL
- ZIP
- 32170
- Mailing
- 137 WEST PUTNAM GROVE ROAD, OAK HILL, FL 32759
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.416 A01
- Issued
- Nov 29, 2016
- Penalty
- Initial $3,741 · Current $2,245 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a. On or about November 8, 2016 employees were working on a scaffold system erected around and above live electrical service wires.
Recent events (2)
- — I (S) $2244.6
- — Z (S) $3741
1926.451 B01
- Issued
- Nov 29, 2016
- Penalty
- Initial $3,741 · Current $2,245 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights; a. On or about November 8, 2016 one employee was working on the top level of a 4 tier welded tubular frame scaffold system that did not have scaffold stages or planks fully decked between the uprights from front to back.
Recent events (2)
- — I (S) $2244.6
- — Z (S) $3741
1926.451 G04 I
- Issued
- Nov 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a. On or about November 8, 2016 one employee was working on the top tier of a 4 tier welded tubular frame scaffold system that did not have guardrails installed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F07
- Issued
- Nov 29, 2016
- Abate by
- Jan 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a. On or about November 8, 2016 three employees were working on the top tier of a four tier welded tubular frame scaffold system. The scaffold system was erected and assembled by the employees, none of which were a competent person defined by the employer to recognize deficiencies and hazards associated with the scaffolds' erection and use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Nov 29, 2016
- Penalty
- Initial $3,741 · Current $2,245 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about November 8, 2016 employees working on a 2 story 6:12 pitch steep slope roof were not protected by complete personal fall protection system, guard rails or safety nets, exposing them to falls in excess of 20 feet to the ground below.
Recent events (2)
- — I (S) $2244.6
- — Z (S) $3741
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341898435.