EL PASO, TX —
OSHA Inspection: COOPER CANYON BOUTIQUE TRAILERS AND TANKS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COOPER CANYON BOUTIQUE TRAILERS AND TANKS, LLC in 4560 RIPLEY DR., EL PASO, TX 79922 (NAICS 327310). OSHA activity number 341900439.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COOPER CANYON BOUTIQUE TRAILERS AND TANKS, LLC
- Site address
- 4560 RIPLEY DR.
- City
- EL PASO
- State
- TX
- ZIP
- 79922
- Mailing
- 4560 RIPLEY, EL PASO, TX 79922
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327310
- Employees
- 17
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 C01
- Issued
- Dec 23, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $4,988 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open sided floors or platforms 4 feet or more above adjacent floor or ground level were not guarded by a standard railing on all open sides. On or about November 08, 2016, the walking access path used by employees to unjam the steel plate lifting device on the conveyor was not guarded by a standard railing on all open sides. This condition exposed employees to fall hazards of greater than 4 feet.
Recent events (2)
- — I (S) $2500
- — Z (S) $4988
1910.95 C01
- Issued
- Dec 23, 2016
- Abate by
- Feb 15, 2017
- Penalty
- Initial $2,850 · Current $1,450 Reduced
General-duty citation text
29 CFR 1910.95(c)(1): A continuing, effective Hearing Conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8-hour Time-Weighted Average sound level (TWA) of 85 decibels (dBA). On or about November 08, 2016, the employer had not instituted a hearing conservation program when employees were being exposed to a Time Weighted Average (TWA) of 85 decibels (dBA) or more. This condition exposed employees to potential hearing loss.
Recent events (2)
- — I (S) $1450
- — Z (S) $2850
1910.212 A03 II
- Issued
- Dec 23, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $3,563 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about November 08, 2016, a sprocket driving a chain conveyor where employees feed steel plates into the molding cinderblock machine was not guarded. This condition exposed employees to caught-between hazards.
Recent events (2)
- — I (S) $1750
- — Z (S) $3563
1910.305 B02 I
- Issued
- Dec 23, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $2,850 · Current $1,450 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(I): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose. On or about November 10, 2016, the junction box next to the Cubber machine was not provided with a cover which left the electrical wires (energized) exposed. This condition exposed employees to electrical shock hazards.
Recent events (2)
- — I (S) $1450
- — Z (S) $2850
1910.305 B03 I
- Issued
- Dec 23, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(3)(i): Boxes shall provide a complete enclosure for the contained conductors or cables. On or about November 8, 2016, two magnetic contactor boxes in the material prep area control room were not provided with covers. This condition exposed employees to electrical shock hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 J01 III
- Issued
- Dec 23, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $2,850 · Current $1,450 Reduced
General-duty citation text
1910.305(j)(1)(iii): Lampholders of the screw-shell type which were supplied by a circuit having a grounded conductor did not have the grounded conductor connected to the screw shell: On or about November 08, 2016, a non-industrial aluminum casing light fixture (screw shell type) used for finished product inspections was not grounded. This condition exposed employees to electrical shock hazards.
Recent events (2)
- — I (S) $1450
- — Z (S) $2850
1910.305 B01 II
- Issued
- Dec 23, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about November 08, 2016, an electrical junction box in the production area had an unused opening. This condition exposed employees to electrical shock hazards.
Recent events (2)
- — I (O) $400
- — Z (O) $400