Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRUNSWICK CONSTRUCTION COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BRUNSWICK CONSTRUCTION COMPANY, INC. in 14 LENNEKE LANE, EAST BRUNSWICK, NJ 08816 (NAICS 237110). OSHA activity number 341901809.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brunswick Construction Company, INC. — free Get an email when a new federal OSHA severe-injury report for Brunswick Construction Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
14 LENNEKE LANE
City
EAST BRUNSWICK
State
NJ
ZIP
08816
Mailing
PO BOX 467, DAYTON, NJ 08810
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 1, 2016
Penalty
Initial $2,672 · Current $1,603 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) 14 Lenneke Lane, East Brunswick NJ:     The employer did not ensure that employees who were working in close proximity to overhead hazards were wearing hard hats.    This hazard was observed on 11/2/16.
Recent events (2)
  • — I (S) $1603
  • — Z (S) $2672

1926.600 A06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 1, 2016
Abate by
Dec 12, 2016
Penalty
Initial $2,672 · Current $1,603 Reduced
29 CFR 1926.600(a)(6)(i): 29 CFR 1926.600(a)(6)(i):  For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment.    a) 14 Lenneke Lane, East Brunswick, NJ:     The employer did not ensure that the Kobelco SK 160LC excavator remained at least 10 feet from overhead energized power lines.    This hazard was observed on 11/2/16.
Recent events (2)
  • — I (S) $1603
  • — Z (S) $2672

View Brunswick Construction Company, INC.'s full OSHA safety record →