Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GERRESHEIMER PEACHTREE CITY (USA), L.P.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GERRESHEIMER PEACHTREE CITY (USA), L.P. in 650 HIGHWAY 74 SOUTH, PEACHTREE CITY, GA 30269 (NAICS 326199). OSHA activity number 341906451.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gerresheimer Peachtree City (USA), L.P. — free Get an email when a new federal OSHA severe-injury report for Gerresheimer Peachtree City (USA), L.P. is published. One employer, no account, unsubscribe in one click.
Site address
650 HIGHWAY 74 SOUTH
City
PEACHTREE CITY
State
GA
ZIP
30269
Mailing
650 HIGHWAY 74 SOUTH, PEACHTREE CITY, GA 30269
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
120
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 1 exposed
Issued
May 4, 2017
Abate by
Jun 30, 2017
Penalty
Initial $9,054 · Current $5,432 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    a) B & C Cleaning Room work station #4081, On or about November 10, 2016 and times prior, the employer exposed maintenance employees to amputation hazards in that they did not develop machine specific lockout/tagout procedures for removing/replacing molds and leaky water lines on molding machines.
Recent events (2)
  • — I (S) $5432
  • — Z (S) $9054

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
May 4, 2017
Abate by
Jun 30, 2017
Penalty
Initial $9,054 · Current $5,432 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.     a) B & C Cleaning Room work station #4081, On or about November 10, 2016 and times prior, the employer exposed maintenance employees to amputation hazards, while removing and replacing molds and water lines, in that lockout/tagout training for the injection molding machines was not provided.
Recent events (2)
  • — I (S) $5432
  • — Z (S) $9054

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
May 4, 2017
Abate by
Jun 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) B & C Cleaning Room, On or about November 10, 2016 and times prior, the employer exposed maintenance employees to amputation hazards in that periodic inspections of the company's lockout/tagout program was not done at least annually.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C07 IV

Other-than-serious 1 instance 2 exposed
Issued
May 4, 2017
Abate by
Jun 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer had not certified that employee training had been accomplished and kept up to date:    a) B & C Cleaning Room work station #4081, On or about November 10, 2016 and times prior, the employer exposed affected employees to amputation hazards in that certification of affected training for the injection molding machines was not maintained.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 D04 III A

Other-than-serious 1 instance 1 exposed
Issued
May 4, 2017
Abate by
Jun 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(iii)(A): Where tagout devices were used with energy isolating devices designed with the capability of being locked, the tag attachment was not fastened at the same point at which the lock would have been attached:    a) B & C Cleaning Room work station #4081, On or about November 10, 2016 and times prior, the employer exposed maintenance employees to amputation hazards in that tag attachments were not used while removing/replacing molds and waterlines on the injection molding machines.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Gerresheimer Peachtree City (USA), L.P.'s full OSHA safety record →