CHARLESTON AFB, SC —
OSHA Inspection: MAINTENANCE ENGINEERS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MAINTENANCE ENGINEERS, INC. in SCARTON PLACE BUILDING 377, CHARLESTON AFB, SC 29404 (NAICS 561730). OSHA activity number 341906725.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAINTENANCE ENGINEERS, INC.
- Site address
- SCARTON PLACE BUILDING 377
- City
- CHARLESTON AFB
- State
- SC
- ZIP
- 29404
- Mailing
- 8901 E PIMA CENTER PKWAY #225, SCOTTSDALE, AZ 85258
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- Employees
- 13
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Dec 7, 2016
- Abate by
- Mar 30, 2017
- Penalty
- Initial $6,236 · Current $2,806 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Corner of Sloan Street and Davis Street: Employees were observed feeding tree branches into a Vermeer wood chipper Model Number BC1800A, without adequate guarding. In the event that an employee would be drawn into the chipper rollers, the control handle located 5 feet way could not be reached. Another form of guarding or control such as a stop bar or extending the distance to the rollers by lengthening the back metal tray is needed to comply. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- — I (S) $2806
- — Z (S) $6236
1910.305 A02 IX
- Issued
- Dec 7, 2016
- Penalty
- Initial $3,741 · Current $1,683 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded. a) East wall of the Main Shop: A fluorescent light used for general illumination was not equipped with a guard or cover to prevent employee or equipment making contact with the bare bulbs.
Recent events (2)
- — I (S) $1683
- — Z (S) $3741
1910.305 J02 IV
- Issued
- Dec 7, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: a) Southeast corner of the Building: A 120 volt receptacle outlet located on the outside of the building and exposed to the elements was missing the weatherproof cover.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Maintenance Engineers, INC.