OSHA Inspection: MAINTENANCE ENGINEERS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MAINTENANCE ENGINEERS, INC. in SCARTON PLACE BUILDING 377, CHARLESTON AFB, SC 29404 (NAICS 561730). OSHA activity number 341906725.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maintenance Engineers, INC. — free Get an email when a new federal OSHA severe-injury report for Maintenance Engineers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
SCARTON PLACE BUILDING 377
City
CHARLESTON AFB
State
SC
ZIP
29404
Mailing
8901 E PIMA CENTER PKWAY #225, SCOTTSDALE, AZ 85258
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
13
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 7, 2016
Abate by
Mar 30, 2017
Penalty
Initial $6,236 · Current $2,806 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Corner of Sloan Street and Davis Street: Employees were observed feeding tree branches into a Vermeer wood chipper Model Number BC1800A, without adequate guarding. In the event that an employee would be drawn into the chipper rollers, the control handle located 5 feet way could not be reached. Another form of guarding or control such as a stop bar or extending the distance to the rollers by lengthening the back metal tray is needed to comply.     ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $2806
  • — Z (S) $6236

1910.305 A02 IX

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 7, 2016
Penalty
Initial $3,741 · Current $1,683 Reduced
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded.    a) East wall of the Main Shop:  A fluorescent light used for general illumination was not equipped with a guard or cover to prevent employee or equipment making contact with the bare bulbs.
Recent events (2)
  • — I (S) $1683
  • — Z (S) $3741

1910.305 J02 IV

Other-than-serious 1 instance 13 exposed
Issued
Dec 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:  a) Southeast corner of the Building:  A 120 volt receptacle outlet located on the outside of the building and exposed to the elements was missing the weatherproof cover.