LITTLE ROCK, AR —
OSHA Inspection: HECTOR CRUZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HECTOR CRUZ in 15524 CHENAL PARKWAY, LITTLE ROCK, AR 72211 (NAICS 238160). OSHA activity number 341907335.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HECTOR CRUZ
- Site address
- 15524 CHENAL PARKWAY
- City
- LITTLE ROCK
- State
- AR
- ZIP
- 72211
- Mailing
- 6716 POPPY ROAD, LITTLE ROCK, AR 72209
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.102 A01
- Issued
- Feb 14, 2017
- Abate by
- Mar 8, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On or about November 14, 2016, and times prior thereto, on a rooftop, employees were installing asphalt shingles using pneumatic nail guns without the use of eye protection, exposed to hazards of flying projectiles.
Recent events (1)
- — Z (S) $3803
1926.451 C02 II
- Issued
- Feb 14, 2017
- Abate by
- Mar 8, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: On or about November 14, 2016 and times prior thereto, on an aluminum scaffold platform, employees installing asphalt roof shingles were using bundles of the shingles as base support for the front of the platform, which created a greater than 9 ft. fall to the ground below.
Recent events (1)
- — Z (S) $3803
1926.452 N03
- Issued
- Feb 14, 2017
- Abate by
- Mar 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(n)(3): Ladders used to support step, platform, and trestle ladder scaffolds shall be placed, fastened, were not equipped with devices to prevent slipping: On or about November 14, 2016 and times prior thereto, on a roof, where employees were installing asphalt shingles, the ladder used to support the work platform for the task involved was not fastened, or equipped with devices to prevent slipping. This condition exposed employee(s) to ladder displacement, which would create a fall hazard.
Recent events (1)
- — Z (S) $0
1926.501 B13
- Issued
- Feb 14, 2017
- Abate by
- Mar 8, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about November 14, 2016, and times prior thereto, employees were observed working on a roof with a pitch of 6:12 at heights greater 6 feet without the use of fall protection, exposing employees to fall hazards.
Recent events (1)
- — Z (S) $3803
1926.1053 B01
- Issued
- Feb 14, 2017
- Abate by
- Mar 8, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On or about November 14, 2016, and times prior thereto, at the jobsite, employees were ascending and descending from the rooftop on an aluminum extension ladder which did not extend at least three feet above the rooftop landing, exposing employees to fall hazards greater than 6 ft. to the ground below.
Recent events (1)
- — Z (S) $2716
1926.1053 B16
- Issued
- Feb 14, 2017
- Abate by
- Mar 8, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: On or about November 14, 2016, and times prior thereto, at the jobsite, the employer did not ensure that a Louisville ladder with visible defects was not withdrawn from service until repaired. This condition exposed employees to fall hazards of greater than 9 feet to the ground below.
Recent events (1)
- — Z (S) $3803
More inspections in this industry (NAICS 238160)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341907335.