Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MJ CELCO, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of MJ CELCO, INC. in 1455 VANDERBILT DRIVE, EL PASO, TX 79935 (NAICS 332119). OSHA activity number 341912418.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MJ Celco, INC. — free Get an email when a new federal OSHA severe-injury report for MJ Celco, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MJ CELCO, INC.
Site address
1455 VANDERBILT DRIVE
City
EL PASO
State
TX
ZIP
79935
Mailing
1455 VANDERBILT DRIVE, EL PASO, TX 79935
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332119
Employees
120
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 2 exposed
Issued
Jan 26, 2017
Abate by
Feb 7, 2017
Penalty
Initial $6,519 · Current $3,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about November 15, 2016, the employer did not ensure that facility grinders were properly guarded. These conditions exposed employees to struck-by hazards.      a) Grinder with no guard by press #9F.    b) Grinder with no guard by the packing area.     c) Grinder with no guard by the TRW Welded Assemblies area.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $6519

1910.215 B09

Serious Gravity 1 4 instances 1 exposed
Issued
Jan 26, 2017
Abate by
Feb 7, 2017
Penalty
Initial $4,889 · Current $3,000 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch    In the Machine shop: On or about November 15, 2016, the distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. This condition exposed employees to struck-by hazards.    a) Right abrasive wheel in Delta grinder the safety peripheral member was exceeded 1/4 inch.    b) Left abrasive wheel in Baldor grinder the safety peripheral member was exceeded 1 1/4 inch.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4889

1910.219 F01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 26, 2017
Abate by
Feb 7, 2017
Penalty
Initial $9,778 · Current $6,000 Reduced
29 CFR 1910.219(f)(1)(i): Sprocket chain was not guarded by a complete enclosure:    On or about November 15, 2016, employer did not ensure that a chain and sprocket running the conveyor belt in press #23 was properly guarded. The guarding was torn at the top exposing the rotating chain. This condition exposed employees to caught-in hazards.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $9778

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $4,889 · Current $3,000 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    On or about November 15, 2015, on the production floor, flexible cords and/or cables were used as a substitute for the fixed wiring of a structures. This condition exposed employees to electrical  shock hazards.     a) Flexible cord was being used to power the grinder located by press #9F.     b) Flexible cords that were providing power to the grinding machine in the machine shop.    c) Flexible cords were being used to provide to provide power to other circuits.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4889

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 26, 2017
Abate by
Feb 7, 2017
Penalty
Initial $4,889 · Current $3,000 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:     On or about November 15, 2016, the strain relief to electrical cables listed below were broken. This condition exposed employees to electrical shock hazards.     a) Strain relief broken on cable connecting from wall to on/off switch of the grinding machine.    b) Strain relief broken on the cable connecting from the on/off switch to the motor of grinding machine.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4889

View MJ Celco, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341912418.