Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G&L SIDING AND ROOFING LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of G&L SIDING AND ROOFING LLC in 215 W. CENTER STREET, BUCYRUS, OH 44820 (NAICS 238170). OSHA activity number 341913143.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G&L Siding and Roofing LLC — free Get an email when a new federal OSHA severe-injury report for G&L Siding and Roofing LLC is published. One employer, no account, unsubscribe in one click.
Site address
215 W. CENTER STREET
City
BUCYRUS
State
OH
ZIP
44820
Mailing
23720 LIME CITY RD LOT #78, PERRYSBURG, OH 43551
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 18, 2016
Abate by
Jan 6, 2017
Penalty
Initial $2,672 · Current $1,250 Reduced
29 CFR 1926.20(b)(1): The employer to did not initiate and maintain such programs as may be necessary to comply with this part.    a. G&L Siding and Roofing LLC jobsite located at 215 W. Center Street, Bucyrus, Ohio:  On or about November 15, 2016, the employer did not ensure safety programs were developed and implemented which cover hazards such as but not limited to ladder and scaffolding safety.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2672

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2016
Abate by
Nov 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.   a. G&L Siding and Roofing LLC jobsite located at 215 W. Center Street, Bucyrus, Ohio:  On or about November 15, 2016, the employer did not ensure employees were protected from 20.4 foot fall hazards when working on a ladder jack scaffold to install siding on the North side of the structure.     b. G&L Siding and Roofing LLC jobsite located at 215 W. Center Street, Bucyrus, Ohio:  On or about November 15, 2016, the employer did not ensure employees were protected from 20.4 foot fall hazards when working on a ladder jack scaffold to install siding on the East side of the structure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 K01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2016
Abate by
Nov 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m).  a. G&L Siding and Roofing LLC jobsite located at 215 W. Center Street, Bucyrus, Ohio:  On or about November 15, 2016, the employer did not ensure ladder jack scaffold platforms did not exceed a height of 20 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 K03

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2016
Abate by
Nov 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.452(k)(3): The ladder jack was not designed and constructed that it will bear on the side rails and ladder rungs or on the ladder rungs alone. If bearing on rungs only, the bearing area shall include a length of at least 10 inches (25.4 cm) on each rung.  a. G&L Siding and Roofing LLC jobsite located at 215 W. Center Street, Bucyrus, Ohio:  On or about November 15, 2016, the employer did not ensure the south end of the ladder jack platform rested on the rungs of the ladder.  The platform was attached to the house's aluminum antenna tower and secured to the extension ladder with a ratchet strap.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B07

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2016
Abate by
Nov 30, 2016
Penalty
Initial $2,672 · Current $1,250 Reduced
29 CFR 1926.1053(b)(7): Ladders shall not be used on slippery surfaces unless secured or provided with slip-resistant feet to prevent accidental displacement. Slip-resistant feet shall not be used as a substitute for care in placing, lashing, or holding a ladder that is used upon slippery surfaces including, but not limited to, flat metal or concrete surfaces that are constructed so they cannot be prevented from becoming slippery.    a. G&L Siding and Roofing LLC jobsite located at 215 W. Center Street, Bucyrus, Ohio:  On or about November 15, 2016, the employer did not ensure  extension ladders used as part of a ladder jack scaffold system were erected on a slip resistant surface.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2672

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341913143.