Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: APEX INSTRUMENTS CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of APEX INSTRUMENTS CORPORATION in 1940 FM 389, BRENHAM, TX 77834 (NAICS 332710). OSHA activity number 341913937.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Apex Instruments Corporation — free Get an email when a new federal OSHA severe-injury report for Apex Instruments Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1940 FM 389
City
BRENHAM
State
TX
ZIP
77834
Mailing
1940 FM 389, BRENHAM, TX 77834
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
14
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 1 1 instance 14 exposed
Issued
Jan 9, 2017
Abate by
Feb 27, 2017
Penalty
Initial $2,138 · Current $1,283 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that compressed air was distributed throughout the shop floor by use of Polyvinyl Chloride (PVC) pipes exposing employees to explosion hazards and sharp flying projectiles in the air due to a rupture in the line.  On or about 16 November 2016, and at times prior thereto, polyvinyl chloride (PVC) piping was used throughout the shop floor for compressed air in which the system was charged to approximately 110 psig, exposing the employees within the shop to the hazard of being struck by flying projectiles.
Recent events (2)
  • — I (S) $1282.8
  • — Z (S) $2138

1910.242 B

Serious Gravity 1 1 instance 10 exposed
Issued
Jan 9, 2017
Abate by
Jan 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.I.  On or about 16 November 2016, and at times prior thereto, employees used compressed air for cleaning of workstations at various machines and work tables in which the air pressure was not reduced to at least 30 psi, exposing the employees to the hazard of being struck by flying debris or to an air embolism.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 10 exposed
Issued
Jan 9, 2017
Abate by
Jan 13, 2017
Penalty
Initial $3,563 · Current $2,138 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  On or about 16 November 2016, and at times prior thereto, the Yama Seiki BM-1020 CNC Mill Machine was used with the interlock bypassed and the door of the machine open while running, exposing the Operator to the hazard of being struck by or caught in rotating parts.
Recent events (2)
  • — I (S) $2137.8
  • — Z (S) $3563

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 9, 2017
Abate by
Jan 13, 2017
Penalty
Initial $2,138 · Current $1,283 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.  On or about 16 November 2016, and at times prior thereto, a pedestal bench grinder was utilized on the shop floor with each tongue guard adjusted beyond one fourth inch, exposing employees using the grinder to a struck by hazard from the wheel disintegrating.
Recent events (2)
  • — I (S) $1282.8
  • — Z (S) $2138

1910.303 B07 I

Serious Gravity 5 4 instances 10 exposed
Issued
Jan 9, 2017
Abate by
Jan 13, 2017
Penalty
Initial $3,563 · Current $2,138 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.  On or about 16 November 2016, and at times prior thereto, unused breaker slots within breaker panels were not effectively closed, exposing employees accessing the panel to an electrical hazard of approximately 220 volts. 1) Breaker Panel near junction box labeled P2 7-8-9 had missing breaker slots 25 through 27 and slot 36. 2) Breaker Panel near transformer had missing slots 1 and 2, plus 17, 19, and 21 which are side by side. 3) Breaker Panel N1 had missing slots 12, 14, and 16 which are side by side. 4) Breaker Panel N-2 had missing slots 4 and 29, 31, 33, 35 which are side by side.
Recent events (2)
  • — I (S) $2137.8
  • — Z (S) $3563

1910.305 B02 I

Serious Gravity 1 1 instance 14 exposed
Issued
Jan 9, 2017
Abate by
Jan 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.  On or about 16 November 216, and at times prior thereto, a two-plug electrical outlet within the break room was missing the faceplate, exposing employees to an electrical hazard of approximately 110 volts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341913937.