PETAL, MS —
OSHA Inspection: FAIRLEY CONSTRUCTION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FAIRLEY CONSTRUCTION in 1272 EVELYN GANDY PARKWAY, PETAL, MS 39465 (NAICS 238130). OSHA activity number 341915247.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FAIRLEY CONSTRUCTION
- Site address
- 1272 EVELYN GANDY PARKWAY
- City
- PETAL
- State
- MS
- ZIP
- 39465
- Mailing
- 828 HIGHWAY 11, PETAL, MS 39465
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.404 B01 II
- Issued
- Jan 5, 2017
- Abate by
- Jan 9, 2017
- Penalty
- Initial $4,490 · Current $1,796 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. (a) Rear of building - on or about November 15, 2016 workers building the commercial building were using receptacles to power their equipment and tools that was supplied by the contractor that were not protected by a ground fault circuit interrupter.
Recent events (2)
- — I (S) $1796
- — Z (S) $4490
1926.405 A02 II A
- Issued
- Jan 5, 2017
- Abate by
- Jan 9, 2017
- Penalty
- Initial $2,181 · Current $1,419 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(A): Temporary wiring feeder conductors were not run as multiconductor cord or cable assemblies or within raceways; or, where not subject to physical damage, run as open conductors on insulators not more than 10 feet apart: (a) South side of building - On or about November 15, 2016 the employer had placed the temporary electrical power to the exterior lights and outlets on the driveway where vehicle traffic must pass multiple times a day with no protection from physical damage or environmental damage.
Recent events (2)
- — I (S) $1418.5
- — Z (S) $2181
1926.405 B01
- Issued
- Jan 5, 2017
- Abate by
- Jan 9, 2017
- Penalty
- Initial $2,726 · Current $1,771 Reduced
General-duty citation text
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed: (a) Rear of building - On or about November 15, 2016 employees using electrical power from panel box on pole is missing two blank cover plates on panel buss bar exposing live wires inside.
Recent events (2)
- — I (S) $1770.5
- — Z (S) $2726
1926.405 E01
- Issued
- Jan 5, 2017
- Abate by
- Jan 9, 2017
- Penalty
- Initial $1,636 · Current $981 Reduced
General-duty citation text
29 CFR 1926.405(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures: (a) Bach of building - On or about November 15, 2016 employees are plugging their extension cords into an job made outlet box that is not weather proof and the parking lot lights wiring is spliced in a ceiling round junction box that is not weather proof.
Recent events (2)
- — I (S) $980.5
- — Z (S) $1636
1926.405 G02 III
- Issued
- Jan 5, 2017
- Abate by
- Jan 9, 2017
- Penalty
- Initial $4,490 · Current $1,796 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used: (a) Rear of building - On or about November 15, 2016 employees were using an electrical extension that was hard wired into the panel box that has two splices that did not retain the insulation factor of the outer sheathing properties.
Recent events (2)
- — I (S) $1796
- — Z (S) $4490
More inspections in this industry (NAICS 238130)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341915247.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.