PORT JERVIS, NY ·
OSHA Inspection: ONE SOURCE HR SOLUTIONS
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of ONE SOURCE HR SOLUTIONS in 20 WEST KING STREET, PORT JERVIS, NY 12771 (NAICS 561320). OSHA activity number 341916625.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ONE SOURCE HR SOLUTIONS
- Site address
- 20 WEST KING STREET
- City
- PORT JERVIS
- State
- NY
- ZIP
- 12771
- Mailing
- 1124 HIGHWAY 315, WILKES BARRE, PA 18702
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561320
- Employees
- 140
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.134 E01
- Issued
- Feb 24, 2017
- Abate by
- Mar 31, 2017
- Penalty
- Initial $12,471 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a). On or about 10/4/16, in the pre-weighting area, for a One Source employee that is required, by Kolmar, to don a Sperian N95 when weighting certain powders that contains allergens. One Source HR Solutions did not provide a medical evaluation for the employee required to don a Sperian N95.
Recent events (3)
- · F (S) $0
- · C (S) $12471
- · Z (S) $12471
1910.134 F01
- Issued
- Feb 24, 2017
- Abate by
- Mar 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a). On or about 10/4/16, in the pre-weighting area, for a One Source employee that is required, by Kolmar, to don a Sperian N95 when weighting certain powders that contains allergens. One Source HR Solutions did not provide a fit test for the employee required to don a Sperian N95.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 561320)