Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GREEN HORIZONS ENVIRONMENTAL, LLC DBA TOMPKINS USA

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of GREEN HORIZONS ENVIRONMENTAL, LLC DBA TOMPKINS USA in 623 ONEIDA STREET, SYRACUSE, NY 13202 (NAICS 333249). OSHA activity number 341916971.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Green Horizons Environmental, LLC DBA Tompkins USA — free Get an email when a new federal OSHA severe-injury report for Green Horizons Environmental, LLC DBA Tompkins USA is published. One employer, no account, unsubscribe in one click.
Site address
623 ONEIDA STREET
City
SYRACUSE
State
NY
ZIP
13202
Mailing
623 ONEIDA STREET, SYRACUSE, NY 13202
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333249
Employees
13
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 3 instances 3 exposed
Issued
Dec 8, 2016
Abate by
Jan 3, 2017
Penalty
Initial $2,423 · Current $1,575 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by the load should the lifting devices fail:    a) Bullard Department, on or about 11/17/16: H-4 1/8 Ton Overhead Yale Hoist had not been inspected on a frequent and periodic basis.      b) Planer Department, on or about 11/17/16: M-3 1/2 Ton Overhead Wright- Way Hoist had not been inspected on a frequent and periodic basis.        c) Vertical Department, on or about 11/17/16: M-6 1/8 Ton Yale Hoist had not been inspected on a frequent and periodic basis.
Recent events (2)
  • — I (S) $1574.95
  • — Z (S) $2423

1910.106 E06 II

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 8, 2016
Penalty
Initial $1,545 · Current $1,004 Reduced
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container:     a)  Paint Area, on or about 11/17/16: Employee dispenses toluene a flammable material from a 55 gallon drum to a secondary container with no means of electrically interconnecting the nozzle and the portable container.
Recent events (2)
  • — I (S) $1004.25
  • — Z (S) $1545

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 8, 2016
Penalty
Initial $1,545 · Current $1,004 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    a)  Horizontal Area, on or about 11/17/16: A Grizzley 6" Bench Grinder had an opening between the work rest and grinding wheel that measured 1/2-inch at the right wheel.
Recent events (2)
  • — I (S) $1004.25
  • — Z (S) $1545

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    a) Horizontal Area, on or about 11/17/16: A Grizzley 6" Bench Grinder had an opening between the tongue guard and grinding wheel that measured 1/2-inch at the right wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Dec 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employer did not ensure that an employee using a tight fitting face-piece respirator was fit tested prior to initial use of the respirator, whenever a different respirator face-piece (size, style, model or make) was used, and at least annually thereafter:   a) Paint Area, on or about 11/17/16: Employee required to wear half face air purifying respirator had not been fit tested on an annual basis. Last fit test was 7/21/15.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0