Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A & H ARMATURE WORKS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of A & H ARMATURE WORKS, INC. in 1330 WEST BANK EXPRESSWAY, WESTWEGO, LA 70096 (NAICS 811211). OSHA activity number 341919009.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & H Armature Works, INC. — free Get an email when a new federal OSHA severe-injury report for A & H Armature Works, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1330 WEST BANK EXPRESSWAY
City
WESTWEGO
State
LA
ZIP
70096
Mailing
1330 WEST BANK EXPRESSWAY, WESTWEGO, LA 70096
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811211
Employees
30
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 8, 2017
Abate by
Feb 23, 2017
Penalty
Initial $3,802 · Current $1,901 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace.      On or about November 16, 2016, throughout the facility, the employer allowed an employee to wear a Bullard 88VX Supplied-Air Respirator (SAR) blasting hood to blast housing components of motors and generators, without ensuring the employee was medically evaluated prior to allowing use of the respirator.
Recent events (2)
  • — I (S) $1901
  • — Z (S) $3802

1910.253 B02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 8, 2017
Penalty
Initial $6,338 · Current $3,169 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use.      On or about November 16, 2016  inside the warehouse, the employer allowed employees to walk and work around pressurized cylinder tanks without having valve covering caps.        a. At the entrance/exit bay door area, three (3) pressurized Oxygen tanks were without valve cover caps.        b. At the entrance/exit bay door area,  two (2) pressurized Acetylene (flammable gas) tanks were without valve cover caps.
Recent events (2)
  • — I (S) $3169
  • — Z (S) $6338

View A & H Armature Works, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341919009.