Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOSE VILLEDA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE VILLEDA in 8176 WHITE CROSS COURT, PICKERINGTON, OH 43147 (NAICS 238170). OSHA activity number 341919843.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jose Villeda — free Get an email when a new federal OSHA severe-injury report for Jose Villeda is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE VILLEDA
Site address
8176 WHITE CROSS COURT
City
PICKERINGTON
State
OH
ZIP
43147
Mailing
6119 DARBY LANE, COLUMBUS, OH 43229
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.404 F06

Serious Gravity 1 2 instances 3 exposed
Issued
Dec 20, 2016
Abate by
Dec 30, 2016
Penalty
Initial $1,604 · Current $1,604
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.  a. On or before November 17, 2016, where employees used an electrically operated air compressor, the ground prong was missing from the plug of the air compressor, thereby exposing employees to a 125 volt electrical contact hazard.  b. On or before November 17, 2016, where employees used an extension cord to provide power to a circular saw, the ground prong was missing from the male plug, thereby exposing employees to a 125 volt electrical contact hazard.
Recent events (1)
  • — Z (S) $1604

1926.405 G02 IV

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 20, 2016
Abate by
Dec 30, 2016
Penalty
Initial $1,604 · Current $1,604
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  a. On or before November 17, 2016, where employees used an electrically operated air compressor, the strain relief of the plug of the air compressor was pulled away from the outer insulating jacket of the cord, thereby exposing employees to a 125 volt electrical contact hazard.
Recent events (1)
  • — Z (S) $1604

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 20, 2016
Abate by
Dec 30, 2016
Penalty
Initial $2,672 · Current $2,672
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a. On or before November 17, 2016, where an employee was working from the porch roof, the employee was not protected from falls, thereby being exposed to a 12 foot, 7 inch fall hazard.