SOUTHAMPTON, NY —
OSHA Inspection: LINE HOME CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LINE HOME CONSTRUCTION, INC. in 20 WYANDANCH LANE, SOUTHAMPTON, NY 11969 (NAICS 238170). OSHA activity number 341928844.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LINE HOME CONSTRUCTION, INC.
- Site address
- 20 WYANDANCH LANE
- City
- SOUTHAMPTON
- State
- NY
- ZIP
- 11969
- Mailing
- 20 STARBOARD RD., HAMPTON BAYS, NY 11946
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Apr 27, 2017
- Abate by
- May 3, 2017
- Penalty
- Initial $1,793 · Current $1,793
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite: Employees working directly under ongoing siding and window work were not using head protection; on or about 11/18/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $1793
1926.451 C02 II
- Issued
- Apr 27, 2017
- Abate by
- May 3, 2017
- Penalty
- Initial $4,183 · Current $4,183
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a) Worksite: Folding ladders placed in an unstable manner on the roof of the first story were used to mount the ladder jack scaffold; on or about 11/18/17. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4183
1926.1053 B04
- Issued
- Apr 27, 2017
- Abate by
- May 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Worksite: Folding ladders were used to mount a ladder jack scaffold platform; on or about 11/18/16. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
1926.451 E01
- Issued
- Apr 27, 2017
- Abate by
- May 3, 2017
- Penalty
- Initial $2,988 · Current $2,988
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) Worksite: Employees were doing siding and window work from a ladder jack scaffold, approximately 14 ft. above the ground and were not provided with an access ladder or similar surface; on or about 11/18/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2988
1926.451 G01 I
- Issued
- Apr 27, 2017
- Abate by
- May 3, 2017
- Penalty
- Initial $4,183 · Current $4,183
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) Worksite: Employees doing window and siding work from a ladder jack scaffold approximately 14 ft. above the ground were not protected from falling; on or about 11/18/16. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4183
1926.1053 B05 I
- Issued
- Apr 27, 2017
- Abate by
- May 3, 2017
- Penalty
- Initial $1,793 · Current $1,793
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a) Worksite: Employees were using a ladder to access the roof of the residential building that was used at an angle such that the ratio between the horizontal distance from the top support to the foot of the ladder was approximately one to one; on or about 11/18/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $1793
More inspections at Line Home Construction, INC.
View Line Home Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341928844.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.