RICHMOND HILL, GA —
OSHA Inspection: CAESARSTONE TECHNOLOGIES USA INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CAESARSTONE TECHNOLOGIES USA INC. in 1 CAESARSTONE DRIVE, RICHMOND HILL, GA 31324 (NAICS 327991). OSHA activity number 341931160.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAESARSTONE TECHNOLOGIES USA INC.
- Site address
- 1 CAESARSTONE DRIVE
- City
- RICHMOND HILL
- State
- GA
- ZIP
- 31324
- Mailing
- 1 CAESARSTONE DRIVE SUITE 100, RICHMOND HILL, GA 31324
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 165
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.23 A08
- Issued
- Apr 24, 2017
- Abate by
- May 18, 2017
- Penalty
- Initial $10,755 · Current $9,755 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded: a) Polish Department, Line 6 and Line 7 - On or about November 22, 2016 and times prior to, employees who stood on quartz slabs that were being moved on rolling conveyors, were exposed to trip and fall and caught-in hazards.
Recent events (2)
- — I (S) $9755
- — Z (S) $10755
1910.147 C04 II
- Issued
- Apr 24, 2017
- Abate by
- Jun 9, 2017
- Penalty
- Initial $12,548 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Throughout Facility - On or about November 21, 2016 and at times prior to, the employer did not develop, document or implement specific procedures to control hazardous energy when performing maintenance and service activities on equipment such as but not limited to jot machines, tilt rolling conveyors, saw rooms, side cut saws, calibration machines, polish machines, and auto loaders thus exposing employees to caught-in, stuck-by, and crushed-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $12548
1910.147 C07 I A
- Issued
- Apr 24, 2017
- Abate by
- May 18, 2017
- Penalty
- Initial $12,548 · Current $12,548
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a) Throughout Facility - On or about November 21, 2016 and times prior to, authorized employees performing servicing and maintenance activities on equipment including but not limited to, the jot machines; saw rooms; tilt rolling conveyors; side cut saws; calibration machines; auto loaders; and polish machines, which had multiple energy sources including pneumatic, electric, and hydraulic did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy associated with each type of equipment, and how to isolate and control the different energy sources, thus exposing employees to caught-in, stuck-by, and crushed-by hazards.
Recent events (2)
- — I (S) $12548
- — Z (S) $12548
1910.147 C06 I
- Issued
- Apr 24, 2017
- Abate by
- May 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Throughout Facility - On or about November 22, 2016 and times prior to, the employer had not conducted an inspection of the energy control procedures on an annual or more frequent basis, thus exposing employees to caught-in, stuck-by, and crushed-by hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Caesarstone Technologies USA INC.