Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAZOR EQUIPMENT SERVICES, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RAZOR EQUIPMENT SERVICES, LLC in 3160 CANTON ROAD, CARROLLTON, OH 44615 (NAICS 532310). OSHA activity number 341931624.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Razor Equipment Services, LLC — free Get an email when a new federal OSHA severe-injury report for Razor Equipment Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3160 CANTON ROAD
City
CARROLLTON
State
OH
ZIP
44615
Mailing
3160 CANTON ROAD, CARROLLTON, OH 44615
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
532310
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.333 C03 I A 2

Other-than-serious 1 instance 1 exposed
Issued
Jan 10, 2017
Abate by
Jan 30, 2017
Penalty
Initial $4,988 · Current $3,492 Reduced
29 CFR 1910.333(c)(3)(i)(A): When an unqualified person is working in an elevated position near overhead lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distances:    29 CFR 1910.333(c)(3)(i)(A)(2): For voltages to ground over 50kV - 10 feet (305 cm) plus 4 inches (10 cm) for every 10kV over 50kV.     a. On or before November 16, 2016, where an employee was operating an aerial lift near a 245 Kv electrical transmission line, a 20 foot minimum standoff distance was not maintained, resulting in an electrical arc from the lines to the aerial lift which caused burns and in-patient hospitalization of the employee.
Recent events (2)
  • — I (O) $3491.6
  • — Z (S) $4988

1910.335 B01

Other-than-serious 1 instance 2 exposed
Issued
Jan 10, 2017
Abate by
Jan 30, 2017
Penalty
Initial $4,988 · Current $3,492 Reduced
29 CFR 1910.335(b)(1): Safety signs and tags. Safety signs, safety symbols, or accident prevention tags shall be used where necessary to warn employees about electrical hazards which may endanger them, as required by 1910.145.    a. On or before November 16, 2016, where an employee was operating an aerial lift near a 245 Kv electrical transmission line, there were no signs warning employees about the hazards of the electrical transmission lines, thereby exposing employees to electrical contact hazards.
Recent events (2)
  • — I (O) $3491.6
  • — Z (S) $4988

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341931624.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.